Download - wte.co.th
Transcript
Appendix-C: Fault Codes No. Fault Name Fault Description 1 Over Current Fault This fault indicates that the unit has tripped due to excessive over current. (550% of the rated current). This fault occurs when the load current exceed the value set under I-Trip Level (B307). This fault gives the instantaneous Over Current trip. A short circuit condition on the output will also cause the unit to display this fault. 2 Under Current Fault This fault occurs when the load current falls below the set value under I-Low Level (B303) for a set time in I-Low Time (B304). This active only during the running condition. 3 I-Unbalance Fault This fault occurs when the current between any two phases differ by the value set under the I-Unbalance Level (B205) for a set time in I Unbalance Delay (B206). 4 Overload Fault The fault active whenever motor current exceeds the value set under the Over Load Setting (B305) and the unit will trip as per the selected overload curve. This fault also occurs whenever the load current exceeds the value set under I- Limit (B301) for a set time in I-Limit Time (B302). 5 Firing Fault A firing fault means that after the firing pulses are sent to the thyristor is not conducting. This would normally occur only if the thyristor has a faulty gate or if the thyristor is open circuit or, one or more thyristors are short-circuited or if the thyristor firing circuit is faulty, or one or more motor windings are open circuited. 6 Over Voltage Fault This fault occurs whenever the input voltage to the unit exceeds +20% of the value set under the Rated Input Voltage (B101). If this fault occurs, this fault is instantaneous in order to protect the unit. 7 Phase Loss Fault This fault will occur when one or more input phases are lost or the input voltage falls below the 30% of the value set under the Rated Input Voltage (B101). 8 External Fault This fault occurs if the external fault input selected at the terminal is missing. This comes from the user. 9 Emergency Stop This fault indicates that the unit has shut down due to the emergency stop command. This also comes from the user. 10 EEPROM Fault This fault indicates that the data received from the EEPROM is incorrect. After reset, it will store default values in the EEPROM memory. 11 Ground Fault This fault indicates that the unit has shut down due to ground fault. Before reset, check that any output is not shorted with the ground. 12 Communication Loss If the slave (main control unit) is not responding to the master (Digital Operation Panel), this fault will occur. It is auto reset type. If the communication resumes, this will be cleared. 13 Phase Direction Fault This fault indicates that the phase sequence at the input to the Soft Starter is reversed. 14 Over Frequency Fault This fault occurs when the line frequency exceeds the +10% of the motor frequency. 15 Under Frequency Fault This fault occurs when the line frequency below the -10% of the motor frequency. 16 Bypass Cont Fault This fault indicates that bypass contactor unable to energies when power is applied, or fails to drop out when power is removed. A Axpert-Opti torque Electronic Soft Starter A.7