Download - wte.co.th

Transcript
Appendix-C: Fault Codes
No.
Fault Name
Fault Description
1
Over Current Fault
This fault indicates that the unit has tripped due to excessive over
current. (550% of the rated current). This fault occurs when the load
current exceed the value set under I-Trip Level (B307). This fault
gives the instantaneous Over Current trip. A short circuit condition on
the output will also cause the unit to display this fault.
2
Under Current Fault
This fault occurs when the load current falls below the set value
under I-Low Level (B303) for a set time in I-Low Time (B304). This
active only during the running condition.
3
I-Unbalance Fault
This fault occurs when the current between any two phases differ by
the value set under the I-Unbalance Level (B205) for a set time in I
Unbalance Delay (B206).
4
Overload Fault
The fault active whenever motor current exceeds the value set under
the Over Load Setting (B305) and the unit will trip as per the selected
overload curve. This fault also occurs whenever the load current
exceeds the value set under I- Limit (B301) for a set time in I-Limit
Time (B302).
5
Firing Fault
A firing fault means that after the firing pulses are sent to the thyristor
is not conducting. This would normally occur only if the thyristor has a
faulty gate or if the thyristor is open circuit or, one or more thyristors
are short-circuited or if the thyristor firing circuit is faulty, or one or
more motor windings are open circuited.
6
Over Voltage Fault
This fault occurs whenever the input voltage to the unit exceeds
+20% of the value set under the Rated Input Voltage (B101). If this
fault occurs, this fault is instantaneous in order to protect the unit.
7
Phase Loss Fault
This fault will occur when one or more input phases are lost or the
input voltage falls below the 30% of the value set under the Rated
Input Voltage (B101).
8
External Fault
This fault occurs if the external fault input selected at the terminal is
missing. This comes from the user.
9
Emergency Stop
This fault indicates that the unit has shut down due to the emergency
stop command. This also comes from the user.
10
EEPROM Fault
This fault indicates that the data received from the EEPROM is
incorrect. After reset, it will store default values in the EEPROM
memory.
11
Ground Fault
This fault indicates that the unit has shut down due to ground fault.
Before reset, check that any output is not shorted with the ground.
12
Communication Loss
If the slave (main control unit) is not responding to the master (Digital
Operation Panel), this fault will occur. It is auto reset type. If the
communication resumes, this will be cleared.
13
Phase Direction Fault
This fault indicates that the phase sequence at the input to the Soft
Starter is reversed.
14
Over Frequency Fault
This fault occurs when the line frequency exceeds the +10% of the
motor frequency.
15
Under Frequency Fault
This fault occurs when the line frequency below the -10% of the
motor frequency.
16
Bypass Cont Fault
This fault indicates that bypass contactor unable to energies when
power is applied, or fails to drop out when power is removed.
A
Axpert-Opti torque Electronic Soft Starter
A.7