Download AXIS_SERVO_DRIVE

Transcript
Axis Attributes
Attribute
Axis Type
Drive Status
AXIS_SERVO_DRIVE DINT
Drive Thermal
Fault Action
D-41
Data Type Access Description
AXIS_SERVO_DRIVE SINT
Tag
Lets you access all the drive status bits in one 32-bit word. This tag is
the same as the Drive Status Bits attribute.
Tag
Bit
Servo Action Status
0
Drive Enable Status
1
Shutdown Status
2
Process Status
3
Bus Ready Status
4
Reserved
5
Home Input Status
6
Reg 1 Input Status
7
Reg 2 Input Status
8
Pos Overtravel Input Status
9
Neg Overtravel Input Status
10
Enable Input Status
11
Accel Limit Status
12
Absolute Reference Status
13
Reserved
14
Reserved
15
Velocity Lock Status
16
Velocity Standstill Status
17
Velocity Threshold Status
18
Torque Threshold Status
19
Torque Limit Status
20
Velocity Limit Status
21
Position Lock Status
22
Power Limit Status
23
Reserved
24
Low Velocity Threshold Status
25
High Velocity Threshold Status
26
GSV
SSV
Fault Action
Value
Shutdown
0
Disable Drive
1
Stop Motion
2
Status Only
3
Publication LOGIX-UM002A-EN-P - February 2006