Download AXIS_SERVO_DRIVE
Transcript
Axis Attributes Attribute Axis Type Drive Status AXIS_SERVO_DRIVE DINT Drive Thermal Fault Action D-41 Data Type Access Description AXIS_SERVO_DRIVE SINT Tag Lets you access all the drive status bits in one 32-bit word. This tag is the same as the Drive Status Bits attribute. Tag Bit Servo Action Status 0 Drive Enable Status 1 Shutdown Status 2 Process Status 3 Bus Ready Status 4 Reserved 5 Home Input Status 6 Reg 1 Input Status 7 Reg 2 Input Status 8 Pos Overtravel Input Status 9 Neg Overtravel Input Status 10 Enable Input Status 11 Accel Limit Status 12 Absolute Reference Status 13 Reserved 14 Reserved 15 Velocity Lock Status 16 Velocity Standstill Status 17 Velocity Threshold Status 18 Torque Threshold Status 19 Torque Limit Status 20 Velocity Limit Status 21 Position Lock Status 22 Power Limit Status 23 Reserved 24 Low Velocity Threshold Status 25 High Velocity Threshold Status 26 GSV SSV Fault Action Value Shutdown 0 Disable Drive 1 Stop Motion 2 Status Only 3 Publication LOGIX-UM002A-EN-P - February 2006
Related documents
Introduction
Local PDF
motion_instr.
ControlLogix Motion Module Overview
1756-UM006G-EN-P, Logix5000 Motion Modules User Manual
SERCOS and Analog Motion Configuration and Startup User Manual
1784-UM003 - Rockwell Automation
hydraulic.
1756-UM525 - Rockwell Automation
4100-5.2, AEC Absolute Encoder Converter, Installation and Setup
Parts Catalog Rider Sweeper AM7D-III(Diesel)
Manual - Gate Depot