1
100m
X1-out / V
10m
1m
100µ
10µ
1µ
1k
2k
4k
10k
20k
40k
100k
Frequency / Hertz
This circuit is to be used in an application that requires the gain of the amplifier to
remain within 2dB of the dc value from 0 to 6kHz. A 1dB ripple specification therefore
seems a reasonable choice. Clearly though the tolerance of the capacitors and resistors
may upset this. To investigate, a Monte Carlo analysis is required. The standard
component tolerances are 10% for capacitors and 1% for resistors. With the example
circuit the tolerances are already applied but the procedure for doing this is as follows:
1.
Select menu item Monte-Carlo|Set All Resistor Tolerances
2.
Enter 1%. (The % is recognised)
3.
Select menu item Monte-Carlo|Set All Capacitor Tolerances
4.
Enter 10%.
The example circuit has already been set up to run 100 steps of Monte Carlo. To view
the settings:
1.
Select menu Simulator|Choose Analysis...
2.
Note in the section Monte Carlo and Multi-step Analysis the Enable multi-step box
is checked.
3.
Press the Define... button.
4.
Note that in the Sweep Mode section, Monte Carlo is selected and in the Step
Parameters section Number of steps has been set to 100.
Start the analysis in the usual way. It takes about 2.5 seconds with a 1.5G P4.
The analysis will be repeated 10 times. Now plot the output of the filter in the usual
way (Probe AC/Noise|dB - Voltage...). The result is the following: