Chapter 4 Schematic Editor
The second pass would then be able to evaluate the expression and resolve <nodelist>
(see below). The value of AD will be calculated according to whatever W is set to.
This is an alternative method of setting MOSFET area and perimeter values. (The
method used with the standard symbols is different in order to remain compatible with
earlier versions).
Note that if the property value contains any of the special characters ('<', '>', '{', '}',
'%'), these will be treated literally. So if for example a property value was {tailres}, no
attempt would be made to evaluate {tailres} in the second pass.
Keyword Summary
The keywords available are summarised in the following table and explained in detail
below.
Keyword
Description
nodelist
Substituted with full list of nodes for device.
pinlist
Substituted with full list of pin names for symbol
node[n]
Substituted for individual node
mappednode
As ‘node’ but order defined by mapping property if
present
pinnames
Equivalent to ‘pinnames: <pinlist>’ except that no
substitution takes place if the /nopinnames switch is
specified for the Netlist command.
mappedpinnames
As pinnames but order is altered according to mapping
property if present
nodename
This is not replaced by any text but signifies that the item
following is a node name. The netlist generator must be
able to identify any text that is a node so that it can
correctly substitute the name when required.
repeat
Start of compound keyword to create a general purpose
repeating sequence
series
Start of compound keyword to create a series
combination
parallel
Start of compound keyword to create a parallel
combination.
step
Used by series and parallel to return sequence number.
if
Conditional on the result of an expression
ifd
Conditional on whether a property is defined