Chapter 7 Analysis Modes
The above shows the status box showing for a 1000 step Monte Carlo analysis using 8
cores. Each line shows the status for each of the 8 processes. Apart from sending back
status information, each of the 8 processes runs completely independently and writes to
its own data file. When the run is complete the data from each processes will be linked
to the main data file. Subsequently you can plot and analyse the results in exactly the
same way as you would a single core run.
Using Fixed Probes with Multi-core Multi-step Simulation
Fixed probes usually plot the simulation results incrementally that is the plots are
updated as the simulation proceeds. With Multi-core Multi-step runs, only the curves
created by the primary process are plotted during the run. The remaining curves will be
plotted automatically once the run is complete.
Data Handling with Multi-core Multi-step
With multiple processes running in parallel all writing data to a single disk, it is
possible in some cases for a disk write bottleneck to develop whereby the simulation
appears to hang temporarily. This problem is particularly acute with large circuits
where a large number of signals are being saved. Each signal being saved is allocated a
buffer in main memory and that buffer is written to disk when it is full. This works well
213