Download Introduction - Direct Source Surplus

Transcript
Programmable
This button can be used
to toggle (on or off) Programable Mode. When
off, Contact Mode is at
its default—Standard
Mode
Figure 11. Contact mode: Programmable.
Summary
When commanded to go to contact, the Z-axis will move up to the bottom of the
Speed Zone at normal velocity. Then it will set the velocity to the Contact Speed.
The Z-axis will then continue at this velocity up to the Contact + Overdrive
amount. If the starting point of the Z-axis is already in the speed zone, the Z-axis
move will start by using the Contact Speed.The contact icon (at the lower-left of
this dialog) turns green when contact is made.
When in this mode and with a Positive Overdrive amount, the chuck will be
above contact at the end of the move. The icon on the main toolbar will display
yellow and the Contact button in the main toolbar will display grey. There is no
actual contact searching that goes on in this mode.
Contact Mode:
Programmable
Parameters
Speed Zone
Speed Zone is the distance before contact that the
Contact Speed will use. When the Speed Zone is 0,
the Contact Speed is disabled.
Contact Speed
At Contact Speed, the velocity is lowered from
Preparations • 17