Programmable This button can be used to toggle (on or off) Programable Mode. When off, Contact Mode is at its default—Standard Mode Figure 11. Contact mode: Programmable. Summary When commanded to go to contact, the Z-axis will move up to the bottom of the Speed Zone at normal velocity. Then it will set the velocity to the Contact Speed. The Z-axis will then continue at this velocity up to the Contact + Overdrive amount. If the starting point of the Z-axis is already in the speed zone, the Z-axis move will start by using the Contact Speed.The contact icon (at the lower-left of this dialog) turns green when contact is made. When in this mode and with a Positive Overdrive amount, the chuck will be above contact at the end of the move. The icon on the main toolbar will display yellow and the Contact button in the main toolbar will display grey. There is no actual contact searching that goes on in this mode. Contact Mode: Programmable Parameters Speed Zone Speed Zone is the distance before contact that the Contact Speed will use. When the Speed Zone is 0, the Contact Speed is disabled. Contact Speed At Contact Speed, the velocity is lowered from Preparations • 17