CVS Compressor RPO 200/300/400/600/800
Malfunctions
9
9.1
Malfunctions
Safety during maintenance work
Refer to chapter 2.5 Safety!
Personal protective equipment
See Chapter 2.4.
Environmental protection
Observe the following information with regard to environmental
protection during maintenance:
„ Remove emerging, used or excessive grease at all lubricating
points that are manually supplied with lubricant and dispose of
in accordance with valid local regulations.
„ Collect exchanged oil in suitable containers and dispose of in
accordance with valid local regulations.
Never restart the compressor after it has been shut off due to a
malfunction without checking the cause and remediating the error.
With malfunctions that cannot be alleviated by means of the following instructions, please contact the supplier (Addresses Æ page 2)!
Malfunction:
Possible cause
Corrective action
Execution
Compressor final
temperature too
high
(max.: 100°C)
Cooling air or suction air temperature too high
Ensure a better aeration and
ventilation of the installation
room.
Specialist
Wrong oil usedl
Add oil as per specifications
(Chapter 8.4.2).
Specialist
Oil level too low
Check oil level and fill oil if
necessary (Chapter 8.4.1).
Operator
Oil filter (100/32) soiled
Replace oil filter
(Chapter 8.9).
Specialist
Oil very aged
Oil change. Clean all parts that
came into contact with the oil.
Replace oil filter and air deoiler
element.
Specialist
Oil cooler on the oil and cooling
air side soiled
Clean oil cooler (Chapter 8.10). Specialist
Thermostat valve in oil circuit
defective
Check thermostat valve and
replace if necessary.
Expert
/electrical specialist
69