Download Operating instructions
Transcript
CVS Compressor RPO 200/300/400/600/800 Malfunctions 9 9.1 Malfunctions Safety during maintenance work Refer to chapter 2.5 Safety! Personal protective equipment See Chapter 2.4. Environmental protection Observe the following information with regard to environmental protection during maintenance: Remove emerging, used or excessive grease at all lubricating points that are manually supplied with lubricant and dispose of in accordance with valid local regulations. Collect exchanged oil in suitable containers and dispose of in accordance with valid local regulations. Never restart the compressor after it has been shut off due to a malfunction without checking the cause and remediating the error. With malfunctions that cannot be alleviated by means of the following instructions, please contact the supplier (Addresses Æ page 2)! Malfunction: Possible cause Corrective action Execution Compressor final temperature too high (max.: 100°C) Cooling air or suction air temperature too high Ensure a better aeration and ventilation of the installation room. Specialist Wrong oil usedl Add oil as per specifications (Chapter 8.4.2). Specialist Oil level too low Check oil level and fill oil if necessary (Chapter 8.4.1). Operator Oil filter (100/32) soiled Replace oil filter (Chapter 8.9). Specialist Oil very aged Oil change. Clean all parts that came into contact with the oil. Replace oil filter and air deoiler element. Specialist Oil cooler on the oil and cooling air side soiled Clean oil cooler (Chapter 8.10). Specialist Thermostat valve in oil circuit defective Check thermostat valve and replace if necessary. Expert /electrical specialist 69