Download Operating instructions

Transcript
CVS Compressor RPO 200/300/400/600/800
Malfunctions
Malfunction:
Possible cause
Corrective action
Execution
Volume flow too
low
Air suction regulator with nonreturn valve (30/55, 30/57) will
not open
Remove air suction regulator
with non-return valve and test
(Chapter 0)
Specialist
2/2-way solenoid valve will not
close
Check the 2/2-way solenoid
valve and replace if necessary
Expert
/electrical specialist
Wrong oil used
Change oil as per specifications (Chapter 8.4.2).
Specialist
Air suction filter (126) plugged
Clean filter and replace cartridge (Chapter 8.8).
Specialist
Air suction cyclone
Check the air suction cyclone
and clean if necessary (Chapter 8.6).
Specialist
Relief valve (supplied on-site) will Check the pressure monitor
not close
(supplied on-site) and the relief
valve
High oil waste at
the compressed
air consumption
location
Suction regulator
with non-return
valve does not
close or open
70
Sieve (88) in the suction line
soiled
Clean sieve (Chapter 8.7).
Expert
/electrical specialist
Specialist
Nozzle with non-return valve (85) Remove the nozzle with nonin the oil suction line obstructed
return valve and check. Clean
or non-return valve
or replace the entire set if necessary.
Specialist
Air deoiler element (65) contaminated, defective or incorrectly
installed (O-ring seal)
Check air deoiler element and
replace if necessary. Ensure
the correct seating of the air
deoiler element (Chapter 0).
Specialist
Wrong oil used
Change oil as per specifications (Chapter 8.4.2).
Specialist
Strong pulsation in the compressed line, e.g. by air dryer
Refit the pulsation damper
and/or fine separator. (Chapter
6.12)
Specialist
2/2 way solenoid valve (220)
defective
Check the 2/2-way solenoid
valve and replace if necessary
Expert
/electrical specialist
Pressure monitor (on site) defective
Check pressure monitor and
replace if necessary.
Expert
/electrical specialist
Regulating piston (30/55) with
non-return valve (30/57) is stuck.
Remove the regulator piston
and ensure smooth, unconstricted movement.
Specialist
Have the compressor refitted
by an authorised workshop.
authorised
workshop