CVS Compressor RPO 200/300/400/600/800 Malfunctions Malfunction: Possible cause Corrective action Execution Volume flow too low Air suction regulator with nonreturn valve (30/55, 30/57) will not open Remove air suction regulator with non-return valve and test (Chapter 0) Specialist 2/2-way solenoid valve will not close Check the 2/2-way solenoid valve and replace if necessary Expert /electrical specialist Wrong oil used Change oil as per specifications (Chapter 8.4.2). Specialist Air suction filter (126) plugged Clean filter and replace cartridge (Chapter 8.8). Specialist Air suction cyclone Check the air suction cyclone and clean if necessary (Chapter 8.6). Specialist Relief valve (supplied on-site) will Check the pressure monitor not close (supplied on-site) and the relief valve High oil waste at the compressed air consumption location Suction regulator with non-return valve does not close or open 70 Sieve (88) in the suction line soiled Clean sieve (Chapter 8.7). Expert /electrical specialist Specialist Nozzle with non-return valve (85) Remove the nozzle with nonin the oil suction line obstructed return valve and check. Clean or non-return valve or replace the entire set if necessary. Specialist Air deoiler element (65) contaminated, defective or incorrectly installed (O-ring seal) Check air deoiler element and replace if necessary. Ensure the correct seating of the air deoiler element (Chapter 0). Specialist Wrong oil used Change oil as per specifications (Chapter 8.4.2). Specialist Strong pulsation in the compressed line, e.g. by air dryer Refit the pulsation damper and/or fine separator. (Chapter 6.12) Specialist 2/2 way solenoid valve (220) defective Check the 2/2-way solenoid valve and replace if necessary Expert /electrical specialist Pressure monitor (on site) defective Check pressure monitor and replace if necessary. Expert /electrical specialist Regulating piston (30/55) with non-return valve (30/57) is stuck. Remove the regulator piston and ensure smooth, unconstricted movement. Specialist Have the compressor refitted by an authorised workshop. authorised workshop