Input / Output Module Types
The Hydro-Control V is fitted with plug-in optically isolated input/output modules, manufactured by OPTO-22.
A range of different input/output modules is available.
Digital Input Module Types
Hydronix
Part No.
0401
0402
0403
OPTO-22
Part No.
G4IDC5
G4IAC5
G4IAC5A
Description
10 - 32 VDC
90 – 140VAC
180 – 280VAC
Digital Output Module Types
Hydronix
Part No.
0404
0405
0406
OPTO-22
Part No.
G40DC5
G40AC5
G40AC5A
Description
5 - 60VDC @ 3A (45ºC), 2A (70ºC).
12 – 140VAC @ 3A (45ºC), 2A (70ºC).
24 – 280VAC @ 3A (45ºC), 2A (70ºC).
Connecting Ancillary Equipment
The Hydro-Control V provides no operating voltage for any external equipment other than the Hydronix
moisture sensor. All external equipment (valves, water meter, alarms, relays etc.) must be provided with
power from an external supply. An example plant-wiring schedule is shown in Fig 38.