Download User manual

Transcript
5.2.14
5.2.15
5.2.16
5.2.17
5.2.18
5.2.19
5.2.20
5.2.21
5.2.22
5.2.23
5.2.24
5.2.25
5.2.26
5.2.27
5.2.28
5.2.29
5.2.30
5.2.31
5.2.32
5.2.33
5.2.34
5.2.35
5.2.36
5.2.37
5.2.38
5.2.39
6.
Object 1800h (Transmit PDO1 Parameter, asynchronous operation mode) ______________ 25
Object 1801h (Transmit PDO12 parameter, synchronous operation mode) ______________ 26
Object 1A00h (Transmit PDO1 Mapping Parameter) ________________________________ 27
Object 1A01h (Transmit PDO2 Mapping Parameter) ________________________________ 28
Object 2001h (Manufacturer Offset) _____________________________________________ 28
Object 2002h (Zeroing of encoder value) _________________________________________ 29
Object 2800h (Send repeat counter for PDO1) ____________________________________ 29
Object 2801h (Send repeat counter for PDO2) ____________________________________ 30
Object 6000h (Operating Parameters) ___________________________________________ 30
Object 6001h (Measuring Units per Revolution [Encoder Resolution]) __________________ 31
Object 6002h (Total Measuring Range [Total Step Number]) _________________________ 31
Object 6003h (Preset value) ___________________________________________________ 32
Object 6004h (Position value)__________________________________________________ 32
Object 6200h (Cycle Timer) ___________________________________________________ 33
Object 6500h (Operating Status) _______________________________________________ 33
Object 6501h (SingleTurn resolution) ____________________________________________ 34
Object 6502h (Number of distinguishable revolutions)_______________________________ 34
Object 6503h (Alarms) _______________________________________________________ 34
Object 6504h (Supported Alarms) ______________________________________________ 35
Object 6505h (Warnings) _____________________________________________________ 35
Object 6506h (Supported Warnings) ____________________________________________ 36
Object 6507h (Profile and Software Version) ______________________________________ 36
Object 6508h (Operating Time) ________________________________________________ 36
Object 6509h (Encoder Zeroing Value) __________________________________________ 37
Object 650Ah (Module Identification) ____________________________________________ 37
Object 650Bh (Serial Number) _________________________________________________ 38
Setting and diagnosing elements_____________________________________38
6.1.
Setting of the Node Identifier (Node ID) __________________________________ 38
6.2.
Setting the baud rate _________________________________________________ 39
6.3.
Diagnosis LEDs _____________________________________________________ 39
7.
Commissioning ___________________________________________________40
7.1.
Switching on the supply voltage________________________________________ 40
7.2.
Sending the position value ____________________________________________ 40
7.2.1.
7.2.2.
7.3.
Asynchronous (cyclic) transmission _____________________________________________ 40
Synchronous transmission ____________________________________________________ 41
Stopping Transmission of the Position Value _____________________________ 41
Date: 21.03.2007
Page 3 of 41
Item no. 83069
Revision status 78/07