Download User manual
Transcript
5.2.14 5.2.15 5.2.16 5.2.17 5.2.18 5.2.19 5.2.20 5.2.21 5.2.22 5.2.23 5.2.24 5.2.25 5.2.26 5.2.27 5.2.28 5.2.29 5.2.30 5.2.31 5.2.32 5.2.33 5.2.34 5.2.35 5.2.36 5.2.37 5.2.38 5.2.39 6. Object 1800h (Transmit PDO1 Parameter, asynchronous operation mode) ______________ 25 Object 1801h (Transmit PDO12 parameter, synchronous operation mode) ______________ 26 Object 1A00h (Transmit PDO1 Mapping Parameter) ________________________________ 27 Object 1A01h (Transmit PDO2 Mapping Parameter) ________________________________ 28 Object 2001h (Manufacturer Offset) _____________________________________________ 28 Object 2002h (Zeroing of encoder value) _________________________________________ 29 Object 2800h (Send repeat counter for PDO1) ____________________________________ 29 Object 2801h (Send repeat counter for PDO2) ____________________________________ 30 Object 6000h (Operating Parameters) ___________________________________________ 30 Object 6001h (Measuring Units per Revolution [Encoder Resolution]) __________________ 31 Object 6002h (Total Measuring Range [Total Step Number]) _________________________ 31 Object 6003h (Preset value) ___________________________________________________ 32 Object 6004h (Position value)__________________________________________________ 32 Object 6200h (Cycle Timer) ___________________________________________________ 33 Object 6500h (Operating Status) _______________________________________________ 33 Object 6501h (SingleTurn resolution) ____________________________________________ 34 Object 6502h (Number of distinguishable revolutions)_______________________________ 34 Object 6503h (Alarms) _______________________________________________________ 34 Object 6504h (Supported Alarms) ______________________________________________ 35 Object 6505h (Warnings) _____________________________________________________ 35 Object 6506h (Supported Warnings) ____________________________________________ 36 Object 6507h (Profile and Software Version) ______________________________________ 36 Object 6508h (Operating Time) ________________________________________________ 36 Object 6509h (Encoder Zeroing Value) __________________________________________ 37 Object 650Ah (Module Identification) ____________________________________________ 37 Object 650Bh (Serial Number) _________________________________________________ 38 Setting and diagnosing elements_____________________________________38 6.1. Setting of the Node Identifier (Node ID) __________________________________ 38 6.2. Setting the baud rate _________________________________________________ 39 6.3. Diagnosis LEDs _____________________________________________________ 39 7. Commissioning ___________________________________________________40 7.1. Switching on the supply voltage________________________________________ 40 7.2. Sending the position value ____________________________________________ 40 7.2.1. 7.2.2. 7.3. Asynchronous (cyclic) transmission _____________________________________________ 40 Synchronous transmission ____________________________________________________ 41 Stopping Transmission of the Position Value _____________________________ 41 Date: 21.03.2007 Page 3 of 41 Item no. 83069 Revision status 78/07