Download User manual

Transcript
Sub-index
01h
Description
COB ID of the PDO1
Access
rw
Data type
UNSIGNED 32
EEPROM
yes
Default
40000180h + Node ID
Sub-index
02h
Description
Transmission Type
Access
ro
Data type
UNSIGNED 8
EEPROM
no
Default
FEh (254)
Sub-index
03h (is not used, access attempt generates error message)
Sub-index
04h (is not used, access attempt generates error message)
Sub-index
05h
Description
Event Timer
Access
rw
Data type
UNSIGNED 16
EEPROM
yes
Value range
1 .. 65535 (1h .. FFFFh); the numerical value corresponds with a multiple of
1ms.
(recordable in the “Pre-Operational” state only)
bit30 = 1: RTR for this PDO not released, bit is
always set
PDO has asynchronous characteristics (PDOs are sent depending on the “Event Timer”). This value cannot be changed!
(recordable in the “Pre-Operational” state only)
The service is disabled by writing the value 0.
The content of this object is identical with object 6200h.
5.2.15 Object 1801h (Transmit PDO12 parameter, synchronous operation mode)
Date: 21.03.2007
Sub-index
00h
Description
largest subindex supported
Access
ro
Data type
UNSIGNED 8
EEPROM
no
Default
5h
Page 26 of 41
Item no. 83069