Download Functional Description Manual

Transcript
DIAX04 Main Spindle Drives
F276 Absolute Encoder Error, Position Offset > P-0-0097
When switching off a drive with an absolute encoder motor (multiturn),
the current actual position is saved. When it is turned back on, the
position given by the absolute encoder is compared with the saved value.
This error is output if the deviation is larger than the parametrized P-00097, Absolute encoder monitor window.
Cause:
1.
Initial startup (stored position invalid).
2.
The axis was moved while machine was off over a distance
exceeding the one parametrized in P-0-0097, Absolute
encoder monitor window.
3.
Incorrect position initialization.
Remedy:
On 1.
Clear error (establish home).
On 2.
The axis was moved while on and now is in position outside
of allowable position.
Check whether another travel command could cause damage.
Then clear error.
On 3.
Danger of accident from unwanted axis movement.
Check home. Given wrong home, then feedback defect.
Replace it (in absolute motor encoders with MHD or MKD motors
replace entire motor).
See Function Description: "Actual position value monitor".
F276 attributes
SS display:
F2/76
Diagnosis:
F276 Absolutgeberfehler, Lageabweichung >
P-0-0097
F276 Absolute encoder error, deviation >
P-0-0097
20
Attachment B: Diagnostics
Diagnosis number:
F276
Error class:
Non-fatal
DOK-DIAX04-SHS-02VRS**-FKB1-EN-P