DIAX04 Main Spindle Drives
S-0-0111, Motor current at standstill
Description:
The "motor current at standstill" is that current at which the motor
constantly generates torque at standstill as est in the motor data sheet.
This value is stored in MHD and MKD motors in the motor feedback. It is
loaded from there with the initial startup of the drive. The value for other
motor types must first be entered.
S-0-0111 - attributes
DOK-DIAX04-SHS02VRS**-FKB1-EN-P
ID number :
S-0-0111
Name in German :
Stillstandstrom Motor
Name in English :
Motor Current at Standstill
Function :
Parameter
Data length:
4Byte
Format :
DEC_OV
Unit in German :
A
Unit in English :
A
Decimal points:
3
Minimum input value :
1
Maximum input value :
500000
Editability:
P23
Storage:
Parameter EEPROM
Validity check:
Phase 3
Extreme check:
yes
Combination check:
no
Cyclical transmission:
no
Attachment A: Parameter Description 89