Transcript
DIAX04 Main Spindle Drives S-0-0111, Motor current at standstill Description: The "motor current at standstill" is that current at which the motor constantly generates torque at standstill as est in the motor data sheet. This value is stored in MHD and MKD motors in the motor feedback. It is loaded from there with the initial startup of the drive. The value for other motor types must first be entered. S-0-0111 - attributes DOK-DIAX04-SHS02VRS**-FKB1-EN-P ID number : S-0-0111 Name in German : Stillstandstrom Motor Name in English : Motor Current at Standstill Function : Parameter Data length: 4Byte Format : DEC_OV Unit in German : A Unit in English : A Decimal points: 3 Minimum input value : 1 Maximum input value : 500000 Editability: P23 Storage: Parameter EEPROM Validity check: Phase 3 Extreme check: yes Combination check: no Cyclical transmission: no Attachment A: Parameter Description 89