Download Functional Description Manual

Transcript
DIAX03 Drive With Servo Function
The assignment of the torque values in the different velocity ranges is
displayed in the following picture:
In this case, 160%
corresponds to the
effective peak
current
P
160%
Pmax
160%
100%
100%
Pn
75%
100%
2
1
3
n
n1
n2
Fig. 5-5: Torque assignment
In range 1, the torque value is the actual torque. 100% = rated torque
In range 2, the torque value is equal to the power.
100% =
rated power according to selection list (The rated power of the motor
rating plate is not relevant here since it could relate to another DC bus
voltage.)
Range 3 is similar to the evaluation of range 2, except that the preset
torque decreases in correspondence to the increasing velocity of the
peak power. For high velocity, the maximum torque value can drop below
100%.
In braking mode, you can reach 50% higher torque values in this range
than in motor operation mode.
User-Defined Settings for the Asynchronous Motor
To operate an asynchronous motor, you have to set the specific DIAX03
motor parameters in the controller. The parameters are stored on the
DSM module and are therefore transferable to another controller.
Note:
Motor-specific parameters are used by all DIAX03 controls (DKR,
DDS2.2) in the same manner. The resulting power characteristics
curve depends on the current and especially on the DC bus
voltage. Several additional parameters are available so the user
can optimize the drive to his requirements.
Scaling Factor Pre-Magnetizing
With the pre-magnetizing scaling factor (P-0-0532), you can set the
active magnetization current.
The following applies:
Effective magnetization current = magnetization voltage x scaling factor pre-magnetizing
Fig. 5-1: Calculation of the Effective Magnetization Current
If the pre-magnetizing scaling factor is at 100%, the motor is completely
magnetized. There is a linear connection between set current and torque
according to the torque constant P-0-0051. The torque builds up without
delay. The drive has perfect servo properties.
5-6
Motor Configuration
DOK-DIAX03-SSE-01VRS**-FKB1-EN-P • 09.96