Download Functional Description Manual
Transcript
DIAX03 Drive With Servo Function The assignment of the torque values in the different velocity ranges is displayed in the following picture: In this case, 160% corresponds to the effective peak current P 160% Pmax 160% 100% 100% Pn 75% 100% 2 1 3 n n1 n2 Fig. 5-5: Torque assignment In range 1, the torque value is the actual torque. 100% = rated torque In range 2, the torque value is equal to the power. 100% = rated power according to selection list (The rated power of the motor rating plate is not relevant here since it could relate to another DC bus voltage.) Range 3 is similar to the evaluation of range 2, except that the preset torque decreases in correspondence to the increasing velocity of the peak power. For high velocity, the maximum torque value can drop below 100%. In braking mode, you can reach 50% higher torque values in this range than in motor operation mode. User-Defined Settings for the Asynchronous Motor To operate an asynchronous motor, you have to set the specific DIAX03 motor parameters in the controller. The parameters are stored on the DSM module and are therefore transferable to another controller. Note: Motor-specific parameters are used by all DIAX03 controls (DKR, DDS2.2) in the same manner. The resulting power characteristics curve depends on the current and especially on the DC bus voltage. Several additional parameters are available so the user can optimize the drive to his requirements. Scaling Factor Pre-Magnetizing With the pre-magnetizing scaling factor (P-0-0532), you can set the active magnetization current. The following applies: Effective magnetization current = magnetization voltage x scaling factor pre-magnetizing Fig. 5-1: Calculation of the Effective Magnetization Current If the pre-magnetizing scaling factor is at 100%, the motor is completely magnetized. There is a linear connection between set current and torque according to the torque constant P-0-0051. The torque builds up without delay. The drive has perfect servo properties. 5-6 Motor Configuration DOK-DIAX03-SSE-01VRS**-FKB1-EN-P • 09.96