Download installation
Transcript
User Manual for POWERLINE 31 series power supply units DIAGNOSTIC OPERATIONS FOR ERRORS REPORTED BY THE UPS Problem Possible cause The unit switched to an error Solution Make sure that the unit is not overloaded, the fans are not blocked, Error code “08”,continuous state due to exceeding and the surrounding temperature is not excessively high. Wait 10 sound signal maximum permitted minutes before powering on the unit in order for to cool it down. If temperature the problem was not eliminated, contact technical support. Disconnect all receivers. Turn off the unit. Make sure that the Error code “09”,continuous Short circuit on the unit’s receivers are not damaged and check whether the UPS has no sound signal internal errors, and the reconnect the receivers. In the event of a output problem concerning the UPS, contact technical support. Error code “05” or “06”, The unit switched to an error continuous sound signal state due to an internal error The UPS switches on in Input voltage or frequency battery mode (MODE “03”) exceeds permitted levels Contact technical support Check the power source Check the receivers and disconnect non-critical receivers. Error code “07”, Receiver overload or short Recalculate the power load and reduce the number of receivers continuous sound signal circuit. connected to the unit. Check whether any of the receivers are damaged. Warning - code “23”, sound signal every 1 second Error code “11”,continuous sound signal The UPS does not operate although the mains voltage is correct Damaged storage cells or loader Contact technical support Low charge level of storage cells or storage cells Check the condition of storage cells disconnected service BYPASS switch damaged Contact technical support The storage cells are not fully Leave the unit connected to the mains for at minimum 10 hours in The battery support time has become shorter charged order to fully charge the storage cells. Unit overload Check the receivers and disconnect non-critical receivers. Storage cell capacity decrease caused by aging The “I” has been pressed for an insufficient period of time The unit does not switch Press the “ON” button for at least 1 second No storage cells are on after pressing the “ON” connected to the unit or the button Replace the storage cells voltage of storage cells is too Check the connection of storage cells or charge the storage cells low Unit error Contact technical support When contacting technical support, please prepare the basic information: - UPS model and series number - when the problem occurred - complete description of the problem, including error codes, sound signals, supply and load status. If you have a UPS designed for long backup times, it is also required to prepare information about the batteries used. 2010/01/25 www.ever.eu 27