Control Computer Messages
Report Alarm 8195
<YY-MM-DD> <hh:mm:ss> NODE=<xxx...x>
** 8195<B> MODADDR=<addr> [PORT=<num>] MODTYPE=<type>
REPORT ALARM: hsmaint: Loss of frame condition
CLASS=21 TASKID=<num>
Rec act: Check the facility and cable connection
Message Explanation
An out-of-frame (OOF) event was detected for 2.5 ± 0.5 seconds, causing a loss-of-frame (LOF)
failure condition to be declared for the indicated module.
When two or more framing-bit errors within a 3-msec period or two or more errors out of five or
less consecutive framing bits is detected for the indicated module, an out-of-frame (OOF) or
severely-errored-framing (SEF) event at the DS1 layer is declared.
NOTE:
If the SMDS CPE is not up, the CPE channel service unit (CSU) or other digital
transmission facility (DTF) equipment may be sending an alarm indication signal
(AIS), all 1s. This causes the Access Interface (AI) module to declare DS1 LOF and
Physical Layer Convergence Procedure (PLCP) LOF.
Recommended Action
Verify that the SMDS CPE equipment, such as a router or CSU is up and running.
Verify the state (LOS, LOF) of the directly connected DTF equipment such as a CSU or
DDM-1000. If it is in sync and not reporting any problems, the problem is probably in the
AI-CSU segment of the facility.
Verify that the cable to the directly connected DTF equipment is secure.
If applicable, follow procedures in the Troubleshooting chapter of the Access Interface
Module Reference for running the AI local loopback diagnostics, and also try looping back to
the CSU.
If there is no directly connected DTF equipment, or the directly connected DTF equipment is
also reporting LOS or LOF, verify that the cables are secure, and that the AI line equalization
and clock options for the indicated module are set correctly.
Follow procedures in the Troubleshooting chapter of the appropriate Trunk Module
Reference or the Access Interface Module Reference for running loopback diagnostics.
Replace hardware as necessary. The Installation chapter of the appropriate module reference
provides information for this procedure.