Control Computer Messages
Report Alarm 8025
<YY-MM-DD> <hh:mm:ss> NODE=<xxx...x>
8025<B> MODADDR=<addr> MODTYPE=<type>
REPORT ALARM: Network ready
Message Explanation
The bridge module has passed all self-tests and the network is ready.
Recommended Action
This is an information message only. No action is needed.
Report Alarm 8030
<YY-MM-DD> <hh:mm:ss> NODE=<xxx...x>
** 8030<B> SHELF=<num>
REPORT ALARM: stat: Module fuse failure
Rec act: Check the flag behind power supply for the blown fuse
Message Explanation
Each slot has a fuse for the 5-volt power going to the module. The fuses are located behind the
power supply on the fuse boards. A fuse for a module on the indicated shelf has failed.
Recommended Action
Enter dstat node and check the 5-VOLT FUSES and the POWER SUPPLY fields, which
show a status of either good or failure, depending on whether a fuse has blown or a failed
power supply has been detected.
If a fuse fails, the fuse flag moves to the top of the fuse window. Determine the fuse location
and replace the failed fuse. The Node Reference provides information for this procedure.
If the fuse continues to fail, follow procedures in the Troubleshooting chapter of the
appropriate module reference to isolate the problem and determine necessary action.
If necessary, replace the module. The Installation chapter of the appropriate module
reference provides information for this procedure.
If a failed power supply is detected, check the power distribution system. The Node
Reference provides information for this procedure.
If the alarm is reported on a link, locate the blown fuse in an MPC7 or an MPC15.