63230-216-230-B1.book Page 251 Monday, August 6, 2007 10:35 AM Control and Monitoring Functions Local Control Description PE50486 Switchgear can be controlled locally using Sepam™ Series 80 units equipped with the mimic-based UMI. The control functions available are: b selecting the Sepam™ control mode b viewing device status on the animated mimic diagram b local control of the opening and closing of all Sepam™ controlled devices Selecting the Sepam™ Control Mode A key-switch on the front of the mimic-based UMI is used to select the Sepam™ control mode. Three modes are available: Remote, Local, or Test. In Remote mode, remote control commands are taken into account. Local control commands are disabled, with the exception of the circuit breaker open command. Remote mode is indicated by the variable V_MIMIC_REMOTE = 1. Local control using the mimic-based UMI In Local mode, remote control commands are disabled, with the exception of the circuit breaker open command. Local control commands are enabled. Local mode is indicated by the variable V_MIMIC_LOCAL = 1. Test mode should be selected for tests on equipment, as in during preventive maintenance operations. All functions enabled in Local mode are available in Test mode. No time-tagged events are sent by the communication link. Test mode is indicated by the variable V_MIMIC_TEST = 1. The Logipam programming software can be used to customize control-mode processing. Mimic Diagram and Symbols A mimic diagram or single-line diagram is a simplified diagram of an electrical installation. It is made up of a fixed background on which symbols and measurements are placed. The mimic diagram editor integrated in the SFT2841 software can be used to personalize and setup mimic diagrams. The symbols that make up the mimic-diagram constitute the interface between the mimic-based UMI and the other Sepam™ control functions. There are three types of symbols: b fixed symbol: represents the electrotechnical devices that are neither animated or controlled, e.g. a transformer b animated symbol with one or two inputs: represents the electrotechnical devices that change on the mimic diagram, depending on the symbol inputs, but cannot be controlled via the Sepam™ mimic-based UMI. This type of symbol is used for switch-disconnectors without remote control, for example. b controlled symbol with one or two inputs/outputs: represents the electrotechnical devices that change on the mimic diagram, depending on the symbol inputs, and can be controlled via the Sepam™ mimic-based UMI. This type of symbol is used for circuit breakers, for example. The symbol outputs are used to control the electrotechnical device: v directly via the Sepam™ logic outputs v by the switchgear control function v by logic equations or the Logipam program. © 2007 Schneider Electric. All Rights Reserved. 63230-216-230B1 251 4