Download - Power Logic

Transcript
ACE959
4-wire RS485 Network Interface
Installation
Function
PE50023
The ACE959 interface performs two functions:
b Electrical interface between Sepam™ and a 4-wire RS485 communication
network
b Main network cable branching box for connecting a Sepam™ with a CCA612
cable.
Characteristics
ACE959 Module
ACE959 4-wire RS485 network connection interface.
Weight
Assembly
Operating temperature
Environmental characteristics
0.441 lb (0.2 kg)
On symmetrical DIN rail
–13°F to +158°F (–25°C to +70°C)
Same as Sepam™ base units
4-wire RS485 Electrical Interface
DE80036
in.
(mm)
3.46
(88)
Standard
Distributed power supply
Power consumption
EIA 4-wire RS485 differential
External, 12 V DC or 24 V DC ±10%
16 mA in receiving mode
40 mA maximum in sending mode
Maximum Length of 4-wire RS485 Network
with Standard Cable
Number of
Sepam™ Units
5
10
20
25
1.18(1)
(30)
Maximum Length with
12 V DC Power Supply
Maximum Length with
24 V DC Power Supply
1000 ft (320 m)
590 ft (180 m)
520 ft (160 m)
410 ft (125 m)
3300 ft (1000 m)
2500 ft (750 m)
1500 ft (450 m)
1200 ft (375 m)
5.67
(144)
(1) 2.8 in (70 mm) with CCA612 cable connected.
Description and Dimensions
A and B Terminal blocks for network cable
C RJ45 socket to connect the interface to the base unit with a CCA612 cable
-wire
6
network
Power supply
or
24 V DC
D Terminal block for a separate auxiliary power supply (12 V DC or 24 V DC)
Grounding terminal
t
DE80129
1 Link activity LED, flashes when communication is active (sending or receiving in
progress).
2 Jumper for 4-wire RS485 network line-end impedance matching with load resistor
(Rc = 150 Ω), to be set to:
b Rc , if the module is not at one end of the network (default position)
b Rc, if the module is at one end of the network.
3 Network cable clamps
(inner diameter of clamp = 0.24 in or 6 mm).
Power supply
or
24 V DC
Connection
b
b
b
-wire
network
Power supply
or
24 V DC
(1) Distributed power supply with separate wiring or included in
the shielded cable (3 pairs).
(2) Terminal block for connection of the distributed power
supply module.
202
63230-216-219-B1
b
b
b
Connection of network cable to screw-type terminal blocks A and B
Connection of the grounding terminal by tinned copper braid with
cross-section ≥ AWG 10 (6 mm²) or cable with cross-section ≥ AWG 12 (2.5
mm²) and length ≤ 7.9 in (200 mm), fitted with a 0.16 in (4 mm) ring lug.
Check the tightness (maximum tightening torque 19.5 lb-in or 2.2 Nm).
The interfaces are fitted with clamps to hold the network cable and recover
shielding at the incoming and outgoing points of the network cable:
v the network cable must be stripped
v the cable shielding braid must be around and in contact with the clamp
The interface is to be connected to connector C on the base unit using a
CCA612 cable (length = 9.8 ft (3 m, green fittings)
The interfaces are to be supplied with 12 V DC or 24 V DC
The ACE959 can be connected to a separate distributed power supply (not
included in shielded cable). Terminal block D is used to connect the
distributed power supply module.
© 2007 Schneider Electric. All Rights Reserved.