Download - Power Logic
Transcript
ACE959 4-wire RS485 Network Interface Installation Function PE50023 The ACE959 interface performs two functions: b Electrical interface between Sepam™ and a 4-wire RS485 communication network b Main network cable branching box for connecting a Sepam™ with a CCA612 cable. Characteristics ACE959 Module ACE959 4-wire RS485 network connection interface. Weight Assembly Operating temperature Environmental characteristics 0.441 lb (0.2 kg) On symmetrical DIN rail –13°F to +158°F (–25°C to +70°C) Same as Sepam™ base units 4-wire RS485 Electrical Interface DE80036 in. (mm) 3.46 (88) Standard Distributed power supply Power consumption EIA 4-wire RS485 differential External, 12 V DC or 24 V DC ±10% 16 mA in receiving mode 40 mA maximum in sending mode Maximum Length of 4-wire RS485 Network with Standard Cable Number of Sepam™ Units 5 10 20 25 1.18(1) (30) Maximum Length with 12 V DC Power Supply Maximum Length with 24 V DC Power Supply 1000 ft (320 m) 590 ft (180 m) 520 ft (160 m) 410 ft (125 m) 3300 ft (1000 m) 2500 ft (750 m) 1500 ft (450 m) 1200 ft (375 m) 5.67 (144) (1) 2.8 in (70 mm) with CCA612 cable connected. Description and Dimensions A and B Terminal blocks for network cable C RJ45 socket to connect the interface to the base unit with a CCA612 cable -wire 6 network Power supply or 24 V DC D Terminal block for a separate auxiliary power supply (12 V DC or 24 V DC) Grounding terminal t DE80129 1 Link activity LED, flashes when communication is active (sending or receiving in progress). 2 Jumper for 4-wire RS485 network line-end impedance matching with load resistor (Rc = 150 Ω), to be set to: b Rc , if the module is not at one end of the network (default position) b Rc, if the module is at one end of the network. 3 Network cable clamps (inner diameter of clamp = 0.24 in or 6 mm). Power supply or 24 V DC Connection b b b -wire network Power supply or 24 V DC (1) Distributed power supply with separate wiring or included in the shielded cable (3 pairs). (2) Terminal block for connection of the distributed power supply module. 202 63230-216-219-B1 b b b Connection of network cable to screw-type terminal blocks A and B Connection of the grounding terminal by tinned copper braid with cross-section ≥ AWG 10 (6 mm²) or cable with cross-section ≥ AWG 12 (2.5 mm²) and length ≤ 7.9 in (200 mm), fitted with a 0.16 in (4 mm) ring lug. Check the tightness (maximum tightening torque 19.5 lb-in or 2.2 Nm). The interfaces are fitted with clamps to hold the network cable and recover shielding at the incoming and outgoing points of the network cable: v the network cable must be stripped v the cable shielding braid must be around and in contact with the clamp The interface is to be connected to connector C on the base unit using a CCA612 cable (length = 9.8 ft (3 m, green fittings) The interfaces are to be supplied with 12 V DC or 24 V DC The ACE959 can be connected to a separate distributed power supply (not included in shielded cable). Terminal block D is used to connect the distributed power supply module. © 2007 Schneider Electric. All Rights Reserved.