Chapter 11 Command and Function Reference
A table with the number of rows and columns equal to the number of logic families
listed in the header. The columns represent outputs and the rows inputs. The entry in
the table specifies the compatibility between the output and the input when connected
to each other. The entry may be one of three values:
OK
Fully compatible
WARN
Not compatible but would usually function. Warn user but
allow simulation to continue.
Not compatible and would never function. Abort
simulation.
ERR
In-In resolution table
A table with the number of rows and columns equal to the number of logic families
listed in the header. Both column and rows represent inputs. The table defines how
inputs from different families are treated when they are connected. The entry may be
one of four values:
ROW
Row take precedence
COL
OK
ERR
Column takes precedence
Doesn't matter. (Currently identical to ROW)
Incompatible, inputs cannot be connected.
Out-out resolution table
A table with the number of rows and columns equal to the number of logic families
listed in the header. Both column and rows represent outputs. The table defines how
outputs from different families are treated when they are connected. The entry may be
one of four values:
ROW
COL
OK
Row take precedence
Column takes precedence
Doesn't matter. (Currently identical to ROW)
ERR
Incompatible, outputs cannot be connected.
Reset
Reset
Frees memory associated with most recent simulation run.
It is not normally necessary to use this command unless available memory is low and is
needed for plotting graphs or other applications. Note that Reset does not delete the
data generated by a simulation only the internal data structures set up to perform a run.
These are automatically deleted at the beginning of a new run.
SaveRhs
SaveRhs [/nodeset] filename
Creates a file containing every node voltage, inductor current and voltage source
current calculated at the most recent analysis point. The values generated can be read
back in as nodesets to initialise the dc operating point solution.