Download MULTITANK SYSTEM - Alpha Control Lab
Transcript
8.12 SAFETYMAX Purpose: Return the maximum allowed liquid level. Synopsis: SLF = get(TankObj, ‘SafetyMax’ ); Description: When the level in a safety-active tank exceeds the maximum level, the pump and the automatic valves are turned off. The control is set by the I/O board to zero regardless of the control value sent out from the MATLAB/Simulink environment. The system returns to the normal operating mode if all levels in safety-active tanks go below the minimum level. This property returns five maximum levels. See: SafetyFlag, SafetyMin, SafetyAlert 8.13 SAFETYMIN Purpose: Return the minimum liquid level that deactivates the safety alert. Synopsis: SLF = get( TankObj, ‘SafetyMin’ ); Description: When the safety alert flag is activated the system returns to the normal operating mode if all levels in safety-active tanks fall under the minimum level. This property returns five minimum levels. See: SafetyFlag, SafetyMax, SafetyAlert 8.14 SAFETYALERT Purpose: Return the safety alert flag. Synopsis: SLF = get( TankObj, ‘SafetyAlert’ ); Description: When the level in a safety-active tank exceeds the maximum level the pump and the automatic valves are turned off. Such conditions trigger the safety