Download Section 6 Usage Precautions

Transcript
Section 6 Usage Precautions
• Example 31
Malfunction during Measurement
No. 31 Example
Malfunction during measurement
Type of device
MOS LSI
Point
The impedance of measurement systems must be appropriate.
Summary of
example/
phenomenon/
cause
During measurement, resistors were connected to the measurement system
(see figure below) to prevent damage. This caused cross-talk between
adjacent input and output pins, thus resulting in a defective input voltage
margin. A single measurement system was shared for testing products with
different pin layouts, with a resistor connected not only to the output pin but
also to the input pin during measurement.
Measurement system
LSI
RΩ
Output
RΩ
Input
Input/output
crosstalk
Countermeasure/
measure of
checking
Modify the system so that the appropriate resistor for protecting the
measurement system can be selected by a relay depending on the pin
specifications (input/output) to allow selecting the 0-Ω resistor for input and
R-Ω resistor for output.
Reference items
6.5.3
Precautions for Board Mounting
Semiconductor devices are not used alone; they are mounted and used on various boards such as
printed-circuit boards, on which other devices are also mounted. Therefore, semiconductor devices
share a power-supply line with other devices and are subject to influence by extraneous signals
used for the circuits located near the semiconductor devices. Special consideration is thus
necessary regarding positioning of the signal lines that are likely to be affected by subtle signal
waveforms.
Rev. 1.00 Aug. 31, 2006 Page 289 of 410
REJ27L0001-0100