Transcript
Section 6 Usage Precautions
(8)
When attaching a power device, use the recommended components (spacer, washer, lug
terminal, screws, nuts, etc.) (see figure 6.15).
Type TO-3
Type TO-220
3-mm diameter screw
3-mm diameter screw
spacer
Metal washer
YZ033S washer
chassis
Insulating washer
3.6 +0.1
−0.08 mm hole diameter
Metal washer
3.3-mm diameter
SK16B spacer
Lug plate
Spring washer
3-mm diameter nut
2.2-mm
diameter
Heat radiating plate
Insulating washer
Metal washer
Spring washer
3-mm diameter nut
Figure 6.15 Example for Attaching a Power Transistor
(9)
Screws that are Used
The screws that are used to attach the device to the heat-sink plate can be classified into cap
screws and self tapping screws; the following precautions are needed in using these.
1. Use binding-cap screws conforming to the JIS-B1101 standard and screws that have heads
equivalent to truss cap screws.
2. Absolutely do not use any flat-head screws since they will apply excessive stress to the device
(figure 6.16).
Rev. 1.00 Aug. 31, 2006 Page 272 of 410
REJ27L0001-0100