Download Section 6 Usage Precautions
Transcript
Section 6 Usage Precautions (8) When attaching a power device, use the recommended components (spacer, washer, lug terminal, screws, nuts, etc.) (see figure 6.15). Type TO-3 Type TO-220 3-mm diameter screw 3-mm diameter screw spacer Metal washer YZ033S washer chassis Insulating washer 3.6 +0.1 −0.08 mm hole diameter Metal washer 3.3-mm diameter SK16B spacer Lug plate Spring washer 3-mm diameter nut 2.2-mm diameter Heat radiating plate Insulating washer Metal washer Spring washer 3-mm diameter nut Figure 6.15 Example for Attaching a Power Transistor (9) Screws that are Used The screws that are used to attach the device to the heat-sink plate can be classified into cap screws and self tapping screws; the following precautions are needed in using these. 1. Use binding-cap screws conforming to the JIS-B1101 standard and screws that have heads equivalent to truss cap screws. 2. Absolutely do not use any flat-head screws since they will apply excessive stress to the device (figure 6.16). Rev. 1.00 Aug. 31, 2006 Page 272 of 410 REJ27L0001-0100