Download MACRO Network Guide
Transcript
Cyclic Registers MACRO Network User Guide 5.4: Auxiliary Register 2 The second 16-bit register value can be programmed to transfer various types of data between the master and slave device. For messages sent from the master to the slave, this register passes a 16-bit value that will be written to the XML model drive’s analog output. For AMP model drives this value is reserved. In order for the analog output value to have any effect, the general purpose analog output of the XML must be configured for manual control. Manual mode can be configured by setting drive parameter 0x134 (or I-variable 0x534) to zero. On response messages sent from the slave device to the master this register's contents are configurable. Bit 8-11 of the MACRO network configuration parameter is used to select the data to be sent back to the master in this register location: 28 Value Data 0 Drive's analog reference input in units of millivolts 1 Lowest 16-bits of the drive's motor encoder input. 2 Lowest 16-bits of the drive’s load encoder input (passive or active). 3 Raw 16-bit value of pulse & direction counter. Copley Controls