Technical Application Papers Bus communication with ABB circuit-breakers Index 1 Introduction. ....................................... 2 2 Digital communication............ 3 2.1 Communication protocols....................... 4 2.1.1 Physical layer.................................................. 5 2.1.1.1 RS-232 and RS-485 interfaces.............. 6 2.1.2 Data link layer................................................. 8 2.1.3 Application layer............................................. 8 2.1.4 Compatibility between the layers................... 9 3 Supervision of electrical distribution plants...................... 10 3.1 Supervision with ABB SACE 4 circuit-breakers...................................... 12 ABB solution for bus communication. ............................ 14 4.1 Emax air circuit-breakers....................... 14 4.2 Emax X1 air-circuit breakers and Tmax T7 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.12 Serial converter RS485/RS232.............. 66 5 ABB circuit-breakers in Ethernet TCP/IP networks.... 67 5.1 Ethernet................................................... 67 5.1.1 IP protocol...................................................... 69 5.1.2 TCP protocol.................................................. 69 5.2 Ethernet industrial protocols................... 70 5.3 Modbus/TCP protocol............................. 71 5.4 Serial Modbus-Modbus/TCP conversion............................................... 74 5.5 SD-GEM gateway.................................... 76 6 Application examples............. 78 6.1 Supervision of protections and Moulded-case circuit-breakers Tmax T4-T5-T6. ...................................... 19 .2 Allocation of the energy costs inside a plant................................. 79 circuit-breaker switching......................... 78 6 Moulded-case circuit-breakers SACE Tmax XT2-XT4 ............................. 22 6.2.1Description of the distribution and communication system.................................. 80 6.2.2Functioning..................................................... 80 SD030DX solution for the circuit-breakers without Modbus RTU.............................. 25 .3 Management of priority and non-prioritary loads................................. 81 6 Front panel interface HMI030. ............... 29 Network Modbus RS-485 (Rules for a correct wiring). .................... 40 4.7.1 Modbus RTU system functioning...................44 Ekip Connect software. .......................... 46 4.8.1 Scanning of the system bus......................... 47 4.8.2 Communication with a single device.............48 Example of product selection for supervision and remote control. ............ 54 DP and DeviceNet fieldbus.................... 56 4.10.1Emax air circuit-breakers E1÷E6, Emax X1 air circuit-breakers and Tmax T7/T7M mouldedcase circuit-breakers...................................57 4.10.2 Moulded-case circuit-breakers Tmax T4-T5-T6............................................59 4.10.3 Moulded-case circuit-breakers SACE Tmax XT2-XT4..................................60 4.11.2 ANR network analyzers...............................62 4.11.3 Temperature control units............................64 4.11.4 Electronic energy meters.............................65 moulded-case circuit-breakers.............. 17 4.10 ABB circuit-breakers in Profibus 4.11 Measuring instruments.......................... 61 4.11.1 DMTME multimeters....................................61 Annex A: Measures, data and commands for supervision and remote control.............................. 82 Annex B: Electrical characteristics of the auxiliary power supply.......................................................... 91 Annex C: The communication modules ................................ 93 Annex D: The measuring modules....................................... 102 Annex E: AUX-E auxiliary contacts and MOE-E motor operator for Tmax T4-T5-T6...................... 104 Annex F: MOE-E motor operator for SACE Tmax XT2-XT4........................................... 106 Annex G: The parity bit........................................................ 108 1