Download 4 - ABB

Transcript
Technical Application Papers
Bus communication with ABB circuit-breakers
Index
1 Introduction. ....................................... 2
2 Digital communication............ 3
2.1
Communication protocols....................... 4
2.1.1 Physical layer.................................................. 5
2.1.1.1 RS-232 and RS-485 interfaces.............. 6
2.1.2 Data link layer................................................. 8
2.1.3 Application layer............................................. 8
2.1.4 Compatibility between the layers................... 9
3 Supervision of electrical
distribution plants...................... 10
3.1 Supervision with ABB SACE
4
circuit-breakers...................................... 12
ABB solution for bus
communication. ............................ 14
4.1 Emax air circuit-breakers....................... 14
4.2 Emax X1 air-circuit breakers and Tmax T7
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.12 Serial converter RS485/RS232.............. 66
5 ABB circuit-breakers in
Ethernet TCP/IP networks.... 67
5.1 Ethernet................................................... 67
5.1.1 IP protocol...................................................... 69
5.1.2 TCP protocol.................................................. 69
5.2 Ethernet industrial protocols................... 70
5.3 Modbus/TCP protocol............................. 71
5.4 Serial Modbus-Modbus/TCP
conversion............................................... 74
5.5 SD-GEM gateway.................................... 76
6 Application examples............. 78
6.1 Supervision of protections and
Moulded-case circuit-breakers
Tmax T4-T5-T6. ...................................... 19
.2 Allocation of the energy
costs inside a plant................................. 79
circuit-breaker switching......................... 78
6
Moulded-case circuit-breakers
SACE Tmax XT2-XT4 ............................. 22
6.2.1Description of the distribution and
communication system.................................. 80
6.2.2Functioning..................................................... 80
SD030DX solution for the circuit-breakers
without Modbus RTU.............................. 25
.3 Management of priority and
non-prioritary loads................................. 81
6
Front panel interface HMI030. ............... 29
Network Modbus RS-485
(Rules for a correct wiring). .................... 40
4.7.1 Modbus RTU system functioning...................44
Ekip Connect software. .......................... 46
4.8.1 Scanning of the system bus......................... 47
4.8.2 Communication with a single device.............48
Example of product selection for
supervision and remote control. ............ 54
DP and DeviceNet fieldbus.................... 56
4.10.1Emax air circuit-breakers E1÷E6, Emax X1 air
circuit-breakers and Tmax T7/T7M mouldedcase circuit-breakers...................................57
4.10.2 Moulded-case circuit-breakers
Tmax T4-T5-T6............................................59
4.10.3 Moulded-case circuit-breakers
SACE Tmax XT2-XT4..................................60
4.11.2 ANR network analyzers...............................62
4.11.3 Temperature control units............................64
4.11.4 Electronic energy meters.............................65
moulded-case circuit-breakers.............. 17
4.10 ABB circuit-breakers in Profibus
4.11 Measuring instruments.......................... 61
4.11.1 DMTME multimeters....................................61
Annex A:
Measures, data and commands for
supervision and remote control.............................. 82
Annex B:
Electrical characteristics of the auxiliary
power supply.......................................................... 91
Annex C:
The communication modules ................................ 93
Annex D:
The measuring modules....................................... 102
Annex E:
AUX-E auxiliary contacts and MOE-E
motor operator for Tmax T4-T5-T6...................... 104
Annex F:
MOE-E motor operator for
SACE Tmax XT2-XT4........................................... 106
Annex G:
The parity bit........................................................ 108
1