Download Advantage21 Programming Manual

Transcript
I/O Control Parameters
Analog Output Functions
One analog output is supplied with the ATV21 drive. The terminal is designated FM.
FM is a multifunctional programmable analog output supplying an output frequency signal as the factory default.
The FM terminal can output a voltage or current signal.
• When switch SW2 is set to V (voltage), FM outputs a 0–10 Vdc signal at 1 mA.
• When switch SW2 is set to I (current), FM outputs a 0–20 mA signal up to 24 Vdc. For detail on proper wiring, consult the ATV21
Installation manual.
The drive value represented by the FM analog output signal is determined by the setting of parameter Analog Output Function Selection
FNSL (see page 83).
Calibrating the FM signal output to provide full scale deflection on an analog meter is achieved by adjusting parameter Analog Output
Scaling FN (see page 83).
The slope and bias of the FM analog output signal can be adjusted using parameters F691 and F692. For more information,
see page 84.
AAV75193 09/20009
79