Download Original instructions
Transcript
4.3.1 Tower top 2) Uncoil wire ropes correctly (Fig. 3). The wire rope coils hang from the suspension beam. Fig. 3 Fig. 1a SWP L Fig. 1b SWP XL Safety wire Guiding wire Guiding wire Traction wire 3) Feed all wire ropes to the bottom of the tower. Top limit stop 1) Fit the top limit device on the traction, safety and left guiding wire ropes (see Fig. 2). Fig. 2a SWP L ! All wire ropes are evenly uncoiled as shown in Fig 3 to prevent looping. Ensure that no obstacles are in the way of the service lift. / Do not pull wire over edges. 4.3.2 Tower bottom Holes in the bottom platform of the tower for wire rope bushing are positioned as shown in Fig. 4a SWP L and Fig. 4b SWP XL. Fig. 4a SWP L Fig 2b. SWP XL Traction wire rope Holes for Power cable bin cable hole straps attachment Guide wire hole Safety wire rope Guide wire hole Wire rope lock Spacer Space for wire rope Plate 5 1 4 2 3 1 2 2 1 1 POS QTY Roller shaft Latch spacer roller d SharkM Wire rope clip for 12mm Wire rope clip for 7-8 mm Top stop plate The spacers must DESCRIPTION ! 45512352 AISI 304 45512243 AISI 304 45512068 45512063 45303726 AW5754 H111 next toNo.the wire MATERIAL ARTICLE be positioned rope locks, opposite to the plate. User’s, Maintenance 21 and Installation Manual