Fig. 18 Wire diameter
12.1.5 Overload limiter/information signs
Annual test:
Test switches as specified in section 5.3 and 5.4 of
the User’s Manual.
Perform overload test as specified on page 61 of
the Installation Guide.
Verify completeness and legibility of all rating
plates and information signs. Replace missing or
illegible plates and signs!
Fig. 19
Wire strap/loop,
which cannot be
unwound
Fig. 20
X402/L502
Loop knot forming
when a wire loop is
pulled tight
Bends resulting from
inappropriate treatment
(e.g. securing the load
with the wire)
M500
Damage resulting from
crushing, squeezing,
running over, etc.
Wire bags
Loop formation
Repairs to traction hoist equipment may ONLY be
performed by the manufacturer or a hoist service
centre, and only using original spare parts.
Table 4
Temperature
range
-15ºC to 80ºC
-35ºC to 40ºC
Synthetic oil
API specification CLPPG or
CLPPG or
PGLP ISO VG 460
PGLP ISO VG 100
Klübersynth
GH6 460
Klübersynth
GH6 100
1)
Oil specification
Use of other synthetic oil only with
approval by AVANTI.
1)
12.2 Repairs
Standard filling
30 AVANTI Service Lift for Wind Turbines
If the gearbox oil needs to be replaced, use one of
the lubricants specified in the following table,
corresponding to the temperature range in which
the traction hoist equipment is used.
Amount required:
traction hoist X402P: 1.4 l.
traction hoist L502P: 1.4 l.
traction hoist M500: 1.4 l.
See table 4.