Download Quick Reference - Whirlpool Corporation

Transcript
Now start...
If codes permit and a separate ground wire is used,
it is recommended that a qualified electrician
determine that the ground path and wire gauge are
in accordance with local codes.
Do Not ground to a gas pipe.
Check with a qualified electrician if you are not sure
range is properly grounded.
Do Not have a fuse in the neutral or ground circuit.
With range in kitchen.
A
If connecting to a fourv&z electrical system...
Do Not connect the cabinet-ground
conductor to the white (neutral) junction
wire.
junction
w
I
B
. THE RANGE MUST BE CONNECTED WITH
COPPER WIRE ONLY.
C
I Wire sizes and connections must conform to
the requirements of the National Electrical Code,
ANSI/NFPA 70 - latest edition (*See Panel A) and
all local codes and ordinances for the kilowatt rating
of the range.
green
wires
D
E
I The wiring diagram is located on the back of
the range or on the inside of the storage drawer in a
clear plastic bag.
m
black
wires
U.L.-listed
conduit
connector
t-H
cable from
range
1. Disconnect the power supply.
2. Separate the green (or bare) and white
appliance cable wires.
3. Connect the white range cable wire to the white
(neutral) wire in the junction box.
4. Connect the two black wires together with twiston connector.
5. Connect the two red wires together with twiston connector.
6. Connect the green range wire to green ground
wire in junction box.
7. Replace junction box cover.
B.
I This range should be connected directly to
the fused disconnect or circuit breaker box through
flexible, armored or non-metallic sheathed, copper
cable (with ground wire). Locate the junction box
to allow two to three feet of slack in the line so
that the range can be moved if servicing is ever
necessary. Do Not cut the conduit.
A U.L.-listed conduit connector must be provided
at each end of the power supply cable (at the
range and at the junction box).
white
wires
%
Figure 1 b ar&
box
cable from
power supply
A
I A four-wire or three-wire, single-phase,
120/240-volt, 60-Hz; 50-amp, AC-only, electrical
supply (or four-wire or three-wire 120/208-volt if
specified on the model/serial rating plate) is
required on a separate 50-ampere circuit, fused on
both sides of the line. A time-delay fuse or circuit
breaker is recommended. The model/serial rating
plate is located on the oven frame behind the
storage drawer panel.
1
Where local codes permit...
connecting the cabinet-ground
conductor
the white (neutral) junction box wire:
junction
box,
green
wire
Figure 2
to
cable from
power supply
I
L
cable from
range
Use B-gauge solid copper wire.
Electrically ground range.
Failure to follow these instructions
death, fire, or electrical shock.
wires.
can result in
This range is manufactured with white (neutral)
power supply wire and a cabinet-connected
bare
ground wire twisted together.
Remove junction box cover.
Connect the range cable to the junction box
through a U.L.-listed conduit connector.
Complete electrical connection according to local
codes and ordinances.
to
cable from
power supply
hardboard.
Tip Over Hazard
A child or adult can tip the range and be
killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range
is moved.
Failure to follow these instructions
can
result in death or serious burns to children
and adults.
n
cable from
range
lay it on
cardboard or hardboard in front of
6range.I Place
Stand range back up onto cardboard or
7 Place the anti-tip
bracket template on the
Grounded
conduit
connector
Neutral
1. Disconnect power supply.
2. Separate the green and white appliance cable
wires.
3. Connect the white range cable wire to the white
(neutral) wire in the junction box.
4. Connect the two black wires together with twiston connector.
5. Connect the two red wires together with twiston connector.
6. Connect the green or bare ground wire from the
range cable to a ground wire in the junction
box.
7. Replace junction box cover.
Panel B
3its back
I Firmly grasp the range and gently
on the cardboard corners.
5
white
Figure 3
1
Failure to do so can result in back or other injury.
I Use an adiustable wrench to loosen the
leveling legs l-l;2 turns.
C Where local codes Do Not
pe;mit...
junction
Excessive weight Hazard
Use two or more people to move and install
range.
4
connector
connecting the cabinet-ground
conductor
the white (neutral) junction box wire:
2 I Take 4 cardboard corners from the carton.
Stack one
cardboard corner
on top of another.
Repeat with the
bcardboard
other two corners.
corners
Place corners
lengthwise on the
floor in back of
range so corners
will support outer
/
\
side edges of range
\/
spacers
as shown.
I Pull cardboard bottom and shipping base
firmly to remove from range.
black
I
Grounded Neutral
1. Disconnect the power supply.
2. Remove the junction box cover.
3. Connect together 3 wires: green and white
range cable wires and the white (neutral) wire in
junction box.
4. Connect the two black wires together with twiston connector.
5. Connect the two red wires together with twiston connector.
6. Replace junction box cover.
Electrical Shock Hazard
Turn power supply off before connecting
I Put on safety glasses and gloves. Remove
shipping materials, tape and protective film from
range. Keep cardboard bottom and shipping base
under range. Remove oven racks and parts
package from inside oven.
floor in
opening
edge is
and the
against
molding
25” (63.5 cm)
countertop
over
the cabinet
so that the left
against cabinets
top edge is
the rear wall,
or cabinet.
j/L-;:
template