Download Quick Reference - Whirlpool Corporation
Transcript
Now start... If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path and wire gauge are in accordance with local codes. Do Not ground to a gas pipe. Check with a qualified electrician if you are not sure range is properly grounded. Do Not have a fuse in the neutral or ground circuit. With range in kitchen. A If connecting to a fourv&z electrical system... Do Not connect the cabinet-ground conductor to the white (neutral) junction wire. junction w I B . THE RANGE MUST BE CONNECTED WITH COPPER WIRE ONLY. C I Wire sizes and connections must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition (*See Panel A) and all local codes and ordinances for the kilowatt rating of the range. green wires D E I The wiring diagram is located on the back of the range or on the inside of the storage drawer in a clear plastic bag. m black wires U.L.-listed conduit connector t-H cable from range 1. Disconnect the power supply. 2. Separate the green (or bare) and white appliance cable wires. 3. Connect the white range cable wire to the white (neutral) wire in the junction box. 4. Connect the two black wires together with twiston connector. 5. Connect the two red wires together with twiston connector. 6. Connect the green range wire to green ground wire in junction box. 7. Replace junction box cover. B. I This range should be connected directly to the fused disconnect or circuit breaker box through flexible, armored or non-metallic sheathed, copper cable (with ground wire). Locate the junction box to allow two to three feet of slack in the line so that the range can be moved if servicing is ever necessary. Do Not cut the conduit. A U.L.-listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box). white wires % Figure 1 b ar& box cable from power supply A I A four-wire or three-wire, single-phase, 120/240-volt, 60-Hz; 50-amp, AC-only, electrical supply (or four-wire or three-wire 120/208-volt if specified on the model/serial rating plate) is required on a separate 50-ampere circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. The model/serial rating plate is located on the oven frame behind the storage drawer panel. 1 Where local codes permit... connecting the cabinet-ground conductor the white (neutral) junction box wire: junction box, green wire Figure 2 to cable from power supply I L cable from range Use B-gauge solid copper wire. Electrically ground range. Failure to follow these instructions death, fire, or electrical shock. wires. can result in This range is manufactured with white (neutral) power supply wire and a cabinet-connected bare ground wire twisted together. Remove junction box cover. Connect the range cable to the junction box through a U.L.-listed conduit connector. Complete electrical connection according to local codes and ordinances. to cable from power supply hardboard. Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. n cable from range lay it on cardboard or hardboard in front of 6range.I Place Stand range back up onto cardboard or 7 Place the anti-tip bracket template on the Grounded conduit connector Neutral 1. Disconnect power supply. 2. Separate the green and white appliance cable wires. 3. Connect the white range cable wire to the white (neutral) wire in the junction box. 4. Connect the two black wires together with twiston connector. 5. Connect the two red wires together with twiston connector. 6. Connect the green or bare ground wire from the range cable to a ground wire in the junction box. 7. Replace junction box cover. Panel B 3its back I Firmly grasp the range and gently on the cardboard corners. 5 white Figure 3 1 Failure to do so can result in back or other injury. I Use an adiustable wrench to loosen the leveling legs l-l;2 turns. C Where local codes Do Not pe;mit... junction Excessive weight Hazard Use two or more people to move and install range. 4 connector connecting the cabinet-ground conductor the white (neutral) junction box wire: 2 I Take 4 cardboard corners from the carton. Stack one cardboard corner on top of another. Repeat with the bcardboard other two corners. corners Place corners lengthwise on the floor in back of range so corners will support outer / \ side edges of range \/ spacers as shown. I Pull cardboard bottom and shipping base firmly to remove from range. black I Grounded Neutral 1. Disconnect the power supply. 2. Remove the junction box cover. 3. Connect together 3 wires: green and white range cable wires and the white (neutral) wire in junction box. 4. Connect the two black wires together with twiston connector. 5. Connect the two red wires together with twiston connector. 6. Replace junction box cover. Electrical Shock Hazard Turn power supply off before connecting I Put on safety glasses and gloves. Remove shipping materials, tape and protective film from range. Keep cardboard bottom and shipping base under range. Remove oven racks and parts package from inside oven. floor in opening edge is and the against molding 25” (63.5 cm) countertop over the cabinet so that the left against cabinets top edge is the rear wall, or cabinet. j/L-;: template