3. Technical Data
The appliance and flue components are packed in separate cartons.
The appliance is for use with Natural Gas only.
The Installation notes in these Instructions, particularly those regarding Maximum Flue Lengths and Configuration
Options, take precedence over any universal instructions included in flue component packs.
TABLE 1 - GENERAL
Gas category
Appliance Type
Minimum rated output
Maximum rated output
Rated input (Net)
Gas rate (CV 34 MJ/m3)
Inlet pressure
Number of injectors
Injector diameter
Injector marking
Burner pressure (max)
Burner pressure (min)
Height
Width
Depth
Dry weight
Gas connection
Hot/cold water connections
Electrical protection
Natural Gas
I2H
C12, C32
10 kW
23.8 kW
27 kW
2.9 m3/hr
20 mbar
14
1.20 mm
120
12.7 mbar
2.5 mbar
700 mm
388 mm
220 mm
20 kg
15mm Copper
15mm Copper
IPX4D
TABLE 2 - FLUE DETAILS
Wall hole size
Standard Horizontal Flue Kit
490mm wall thickness rear outlet
400mm wall thickness side outlet
Horizontal Flue Kit
680mm wall thickness rear outlet
590mm wall thickness side outlet
Flue Extension 1m
90° Bend Kit
135° Bend Kit
Telescopic Flue In Line Elbow Adaptor
Vertical Adaptor
Concentric Vertical Flue Kit
110 mm Diameter
Sales Code B4286
Sales Code 31/19034
Sales Code 31/19035
Sales Code 430174
Sales Code 238014
Sales Code 238015
Flat roof flashing kit
Pitched roof flashing kit
Wall liner / internal flue fixing kit
Terminal guard
Sales Code 31/19040
Sales Code 31/19041
Sales Code 238012
Sales Code 205792
Sales Code 430183
Sales Code 430184
TABLE 3 - PERFORMANCE
Maximum cold water supply inlet pressure
Minimum cold water supply inlet pressure to operate the appliance
Domestic hot water delivery with temperature control knob fully anticlockwise
Domestic hot water delivery with temperature control knob fully clockwise
6
12 bar
0.3 bar
4 to 14 litres/minute at
25°C temperature rise
3 to 6 litres/minute at
55°C temperature rise