Download Bosch C1210ES Specifications
Transcript
Installation instructions | 13 4.3.2 Vent specifications Establish vent clearances that comply with the vent manufacturer's specifications and all applicable national/local codes. 4" Venting Venting specifications E x h a u s t I n t a k e Diam. 3 or 4 inches Approved terminals “T” terminal 90° elbow PVC Flue Cap*(ECAP321)Vertical terminations only 3" diameter only Concentric (196016) “T” terminal 3 or 4 inches 90° elbow PVC Flue Cap*(ECAP321)Vertical & horizontal terminations approved 3" diameter only Concentric (196016) Twin pipe system Concentric system Maximum allowable Exhaust pipe length 63ft Combustion air pipe length 63ft 90° 2.5ft 45° 1.5ft 43ft 43ft 2.5ft 1.5ft Table 9 Maximum Allowable Exhaust and Combustion Air Lengths for 4" venting Use of elbows It is recommended to limit the amount of elbows used in the exhaust and combustion air piping to reduce friction in the air flow. The following lists the maximum amount of 90° elbows allowed in either the exhaust or combustion air piping: Table 7 Venting specifications for intake and exhaust Max. number of 90° elbows Twin pipe system Concentric system [*] Table 10 ULC S636-95, UL1738 certified Condensate drain requirements When the Water Heater is installed in a residential single family dwelling without direct recirculation an external condensate drain is not required. If the Water Heater is installed in an application other than a residential single family dwelling an external condensate drain (not supplied with the Water Heater) is required in the following circumstances: • Vertical terminating exhaust vent installations. • Horizontal terminating exhaust vent installations greater than 6 feet (1.8 m) linear measurement, (NOT total equivalent length). • Vent installations where any section of the exhaust vent pipe passes through an unconditioned space. System used Number of 90° elbows needed: Number of 45° elbows needed: Minimum combustion air and exhaust pipe length The minimum exhaust pipe length is 1 foot (0.3m) of straight vent pipe. The minimum combustion air pipe length is one 90° elbow. Calculation of example Max. length 90° elbow reduction sub-total = 45° elbow reduction Total = Twin pipe system Concentric system Maximum allowable Exhaust pipe length 31ft Combustion air pipe length 31ft 90° 5 ft 45° 3 ft 23ft 23ft 5 ft 3 ft 4" venting 7 7 Calculation example for 3" venting: Exhaust Table 11 3" Venting 3" venting 5 4 Two 45° elbows are equal to one 90° elbow. Any combination of 45° and 90° elbows may be used in the vent system as long as the combination does not exceed the maximum listed in table 10 above. Note: An external condensate drain is recommended in all installations as best practice in order to maximize the longevity of the Water Heater. Maximum combustion air and exhaust pipe length The following tables display the maximum allowable straight pipe lengths for combustion air and exhaust piping with consideration to the number of elbows used. Reduce the equivalent length for each elbow used from the maximum allowable length depending on the system used. Refer to table 8 if using 3" diameter venting. Refer to table 9 if using 4" diameter venting. Elbow Equivalency Concentric 1 2 23’ - 5’ 18’ - 6’ 12’ Table 12 For this example, the maximum allowable exhaust pipe length is 12 feet. Elbow Equivalency Combustion air Table 8 Maximum Allowable Exhaust and Combustion Air Lengths for 3" venting System used Number of 90° elbows needed: Number of 45° elbows needed: Concentric 2 1 Table 13 Calculation of example Max. length 90° elbow reduction sub-total = 45° elbow reduction Total = 23’ - 10’ 13’ - 3’ 10’ Table 14 C 1210 ES/ESC 6 720 644 887 (2014/11)