Download Bosch C1210ES Specifications

Transcript
Installation instructions | 13
4.3.2 Vent specifications
Establish vent clearances that comply with the vent manufacturer's
specifications and all applicable national/local codes.
4" Venting
Venting specifications
E
x
h
a
u
s
t
I
n
t
a
k
e
Diam.
3 or 4 inches
Approved terminals
“T” terminal
90° elbow
PVC Flue Cap*(ECAP321)Vertical terminations
only 3" diameter only
Concentric (196016)
“T” terminal
3 or 4 inches
90° elbow
PVC Flue Cap*(ECAP321)Vertical & horizontal
terminations approved 3" diameter only
Concentric (196016)
Twin pipe
system
Concentric
system
Maximum
allowable
Exhaust pipe
length
63ft
Combustion air
pipe length
63ft
90°
2.5ft
45°
1.5ft
43ft
43ft
2.5ft
1.5ft
Table 9 Maximum Allowable Exhaust and Combustion Air Lengths for 4"
venting
Use of elbows
It is recommended to limit the amount of elbows used in the exhaust and
combustion air piping to reduce friction in the air flow. The following lists
the maximum amount of 90° elbows allowed in either the exhaust or
combustion air piping:
Table 7 Venting specifications for intake and exhaust
Max. number of 90° elbows
Twin pipe system
Concentric system
[*]
Table 10
ULC S636-95, UL1738 certified
Condensate drain requirements
When the Water Heater is installed in a residential single family dwelling
without direct recirculation an external condensate drain is not required.
If the Water Heater is installed in an application other than a residential
single family dwelling an external condensate drain (not supplied with
the Water Heater) is required in the following circumstances:
• Vertical terminating exhaust vent installations.
• Horizontal terminating exhaust vent installations greater than 6 feet
(1.8 m) linear measurement, (NOT total equivalent length).
• Vent installations where any section of the exhaust vent pipe passes
through an unconditioned space.
System used
Number of 90° elbows needed:
Number of 45° elbows needed:
Minimum combustion air and exhaust pipe length
The minimum exhaust pipe length is 1 foot (0.3m) of straight vent pipe.
The minimum combustion air pipe length is one 90° elbow.
Calculation of example
Max. length
90° elbow reduction
sub-total =
45° elbow reduction
Total =
Twin pipe
system
Concentric
system
Maximum
allowable
Exhaust pipe
length
31ft
Combustion air
pipe length
31ft
90°
5 ft
45°
3 ft
23ft
23ft
5 ft
3 ft
4" venting
7
7
Calculation example for 3" venting:
Exhaust
Table 11
3" Venting
3" venting
5
4
Two 45° elbows are equal to one 90° elbow. Any
combination of 45° and 90° elbows may be used in
the vent system as long as the combination does not
exceed the maximum listed in table 10 above.
Note: An external condensate drain is recommended in all installations
as best practice in order to maximize the longevity of the Water Heater.
Maximum combustion air and exhaust pipe length
The following tables display the maximum allowable straight pipe
lengths for combustion air and exhaust piping with consideration to the
number of elbows used. Reduce the equivalent length for each elbow
used from the maximum allowable length depending on the system
used. Refer to table 8 if using 3" diameter venting. Refer to table 9 if
using 4" diameter venting.
Elbow
Equivalency
Concentric
1
2
23’
- 5’
18’
- 6’
12’
Table 12
For this example, the maximum allowable exhaust pipe
length is 12 feet.
Elbow
Equivalency
Combustion air
Table 8 Maximum Allowable Exhaust and Combustion Air Lengths for 3"
venting
System used
Number of 90° elbows needed:
Number of 45° elbows needed:
Concentric
2
1
Table 13
Calculation of example
Max. length
90° elbow reduction
sub-total =
45° elbow reduction
Total =
23’
- 10’
13’
- 3’
10’
Table 14
C 1210 ES/ESC
6 720 644 887 (2014/11)