Download Lucent Technologies 555-661
Transcript
MERLIN LEGEND Communications System Release 6.1 Installation 555-661-140 Unit Load Calculation Worksheet Unit Load Worksheet Issue 1 August 1998 Page B-2 Unit Load Worksheet 1. Number of modules in carrier (excluding power supply and processor: ■ If fewer than five, power is adequate. ■ If five or six, continue to Step 2. 2. Key or Behind Switch mode only: Indicate configuration of lines; then go to Step 5. __________ o Square o Modified 3. Hybrid/PBX mode only: Do all modules in the carrier have MLX and/or analog multiline telephone jacks? ■ If no, a newer power supply is not needed. ■ If yes, continue to Step 4. o Yes o No 4. Hybrid/PBX mode only: Calculate the total number of MLX and analog multiline telephones: Number of MLX-20L consoles connected to modules in the carrier Number of MLX-28D consoles connected to modules in the carrier Number of 34-button analog multiline telephones connected to modules in the carrier Total of MLX-20L, MLX-28D, and 34-button analog telephones ■ If total is less than or equal to 45, auxiliary power is not required. ■ If the total is greater than 45, continue to Step 5. __________ __________ __________ __________