Page 2 of 2 220V Targa and Premier —Large Sizes by Draper Case Dimensions Types of Installation Case Dimensions (Premier Tab Tension Surface Shown) Ceiling Mounted Wall Mounted 16.8 cm Surface Width + A 16.8 cm Appropriate hardware provided by installer. Appropriate hardware provided by installer. 10 cm 8.6 cm 8.6 cm 1 cm R73 cm 63 mm 1.7 cm B Product is very heavy: Installer must provide adequate attachment hardware and anchors as required. Installer must also insure that wall or ceiling structure is of adequate strength. Tab-Tension Adjustment Procedure for Premier Dim Targa Premier A 22.54 cm Varies B 7.62 cm Varies Wiring Diagrams ① Determine which side requires adjustment. ② Secure dowel with one hand. Caution: Do not touch or bend surface. ③ Using Philips-head screwdriver, Tensioning depress spring-loaded Cable adjustment screw (see drawing) and slowly turn clockwise Dowel Adjustment to tighten tension, or Screw counterclockwise to loosen tension. The screw adjusts in ¼ turn increments. Adjust only one increment (¼ turn). ④ If problem is not corrected, leave screen in position for 24 hours to allow surface material to stretch into position. ⑤ If problem still is not corrected, repeat steps 2 and 3. Please Note: Do not wire motors in parallel. Single Station Control Junction box at left end of screen CE Approved Junction box at left end of screen Multiple Station Control Not CE Approved Internal Screen Wiring Blue-220v (Common) Brown-220v (Down) Black-220v (Up) Internal Screen Wiring Blue-220v (Common) Brown-220v (Down) Black-220v (Up) Green (Motor Ground) Green (Motor Ground) Cap off with wire nut & tape Blue Red Blue Black Hot Neutral L1 Black Red Neutral Location of key operated on-off Eye Port for IR Eye. For RF Receiver or LED switch if furnished Wall Switch, a Splitter and a Power Supply is required. Plug RF Receiver or LED Wall Switch and Power Supply into splitter, then run cable from Splitter to MC1 Eye Port. To AC Line Blue Red 220v, 50 Hz. Dashed wiring by installer 220v, 50 Hz. Low Voltage & Wireless Control Internal Screen Wiring White/Blue (Common) Red 110/Black 220 (Up) Black 110/Brown 220 (Down) Green 110V/ Green/Yellow 220V (Motor Ground) White or Blue-Common to screen & 110/220V AC Neutral Red-to screen (directional) Brown-to screen (directional) Yellow-to 110/220V AC-Hot Black-to 110/220V AC-Hot Green(Ground) Dashed wiring by electrician Low voltage wiring by others Eye Port for IR Eye, RF Receiver or LED Wall Switch. For more than one of these, a splitter is required. 3 Button Wall Switch DOWN - Black COM - White UP - Red MC1 RS232 Data FROM Control System RS232 Data TO Control System Signal Ground & Manual Switch Common Manual Switch Down Manual Switch Up Low Voltage Wiring by others AC Wiring by electrician Dashed wiring by installer Fuse Program LED Black Control switch White/Blue (Common) Red 110/Black 220 (Up) Black 110/Brown 220 (Down) Green 110V/ Green/Yellow 220V (Motor Ground) White or Blue-Common Red-to Screen (directional) Black-to Screen (directional) Brown-Hot to AC Green/Yellow-Ground Internal Screen Wiring Two-Way Serial Communication (RS232) with MC1 Aux Port for connecting additional LVC-III modules (up to six total can be linkedconnect from Aux to Eye). See separate Serial CommunicationRS232 Instruction sheet for enabling RS232 with the MC1. www.draperinc.com (765) 987-7999 To 110/220V Line STOP STOP Control Switches 24v DC Location of key operated on-off switch if furnished