Download Draper 220V User's Manual
Transcript
Page 2 of 2 220V Signature/Series E & V by Draper Case Dimensions and Methods of Installation 38 mm Typ Tab-Tensioning Cable Adjustment Case length Ceiling grid and tile (by others) A Series A E-small case 81 mm E-large case 114 mm V Varies 54 mm Viewing surface NOTE: Viewing surface shown is Series V with tab tensioning. Series E, without tab tensioning, is also available. Small Signature Case Shown with 9.5 mm 152 threaded rod mm (provided by others). 248 cm Draper’s Tab-Tensioning System is factory-set, and under normal circumstances will not require field adjustment. If, however, you notice wrinkles, waves, or other indications that the tensioning cables need to be adjusted, follow the procedure below. Tensioning Cable ➀ Determine which side requires adjustment. ➁ Secure dowel with one hand. Caution: Do not touch or bend surface. Dowel Adjustment ➂ Using Philips-head screwdriver, depress Screw spring-loaded adjustment screw (see Fig. 1) and slowly turn clockwise to tighten tension, or counterclockwise to loosen tension. Figure 1 The screw adjusts in ¼ turn increments. Adjust only one increment (¼ turn). ➃ If problem is not corrected, leave screen in position for 24 hours to allow surface material to stretch into position. ➄ If problem still is not corrected, repeat steps 2 and 3. Wiring Diagrams Audience Electrical connection to internal splice box on left end of case. 22mm knockout for 13 mm conduit. J-Box cover located under splice box. Single Station Control Multiple Station Control CE Approved Not CE Approved Terminal strip in junction box at left end of screen Terminal strip in junction box at left end of screen 232 cm Ceiling grid and tile (by others) Cap off with wire nut & tape Large Signature Case Blue Red 152 mm Black Control switch 230V, PE 50 Hz. 232 cm Ceiling grid and tile (by others) Eye Port for IR Eye, RF Receiver or LED Switch For more than one of these, a splitter is required. 3 Button Wall Switch DOWN - Black COM - White UP - Red MC1 Aux Port for connecting additional LVC-III modules (up to six totalconnect from Aux to Eye). Hot Neutral Low Voltage Wiring by others AC Wiring by electrician Eye Port for IR Eye. For RF Receiver or LED Wall Switch, a Splitter and a Power Supply is required. Plug RF Receiver or LED Wall Switch and Power Supply into splitter, then run cable from Splitter to MC1 Eye Port. All-Pole Disconnect by Others STOP STOP 230V, 50 Hz. Control Switches 24v DC www.draperinc.com (765) 987-7999 Hot Neutral Red-to screen (directional) Brown-to screen (directional) White-Common to screen, 110-120V AC Black-to 110-120V AC Yellow-to 110-120V AC Green-Ground Dashed wiring by electrician Low voltage wiring by others Terminal strip in junction box at left end of screen RS232 Data FROM Control System RS232 Data TO Control System Signal Ground & Manual Switch Common Manual Switch Down Manual Switch Up Dashed wiring by electrician Terminal strip in junction box at left end of screen MC1 Fuse Black Low Voltage & Wireless Control See separate Serial Communication-RS232 Instruction sheet for enabling RS232 with the MC1. Red-to Screen (directional) Black-to Screen (directional) Blue-Common Brown-Hot to 230V AC Green/Yellow-Ground Blue 230V, 50 Hz. SCREEN SIZE CASE SIZE Total Drop < 396 cm or viewing width < 366 cm Small Total Drop > 396 cm or viewing width > 366 cm Large Program LED Neutral Dashed wiring by electrician Black Red Hot Audience Neutral 280 cm Electrical connection to internal splice box on left end of case. 22mm knockout for 13 mm conduit. J-Box cover located under splice box. Blue Red L1 Shown with 11 mm threaded rod (provided by others). STOP All-Pole Disconnect by Others STOP 230V, 50 Hz. Control Switches 24v DC