MVHR components: Heat exchanger: Fans: Filters: Central control unit: (for option 1) with defroster and backup duct heater option (for option 2) Housing: Duct connections: Condensate drain: Weight: Electrical connection: Protection class (acc. to EN 60335): International protection (acc. to DIN 40050): Cable length: Operation limit: Mounting position: Material: HX plastic 48 V DC (DC radial fan) Filter class: G 4 (supply/extract air) Option: pollen filter F 8 (supply air) – higher pressure loss Lx Wx D (mm): 340x 300x 80 Lx Wx D (mm): 340x 300x 140 Lx Wx D (mm): 340x 300x 80 Galvanized steel plate, no thermal bridges, 40 mm heat insulation, sound-insulated diameter 125 mm nipple measure hose ¾“ (syphon – supplied by customer) 45 kg 230 V, 50 Hz, pre-wired I IP 41 (MVHR) IP 20 (Control unit) - mains cable: (by customer) - between MVHR and central control unit: 3 m - between central control unit and control panel: max. 15 m, (4-wire, screened control wire IYSTY 2x2x0,6), supplied by customer max. 40°C horizontal, 2 % slope to condensate drain Operating data: Power input: Volumetric flow rate: Heat recovery rate: Sound pressure level Acc. to DIN EN ISO 3743-1: max. 110 W 30 to 180 m³/h - 150 m³/h (at 100 Pa) approx. 80 to 95 % Fan stage / control Step 1 Step 3 Step 5 Step 7 ca. 30% ca. 50% ca. 70% ca.100% 3m distance in free field With installation in intermediate cover Acc. to DIN 4109 Bbl. 1Tab. 26 23 dB(A) 27 dB(A) 32 dB(A) 33 dB(A) < 20 dB(A) Control: Option 1: Automatic control Standard functions • 8 independent time programs can be defined and assigned to any day of the week • Manual adjustment of ventilation steps (off, minimum,normal,maximum) • Control panel can be installed in any place in the house • Ventilation steps programmable in 1% increments (30-100 % of maximum fan power) • Adjustable balance between supply and extract air fans • Filter monitor for change interval • Freeze protection for downstream hot water duct heater • Manual stop in standby mode with limited power input below 2 W Options (available at extra cost) • Control of an electric valve (direct air intake or via ground heat exchanger) or a brine-defroster (brine/air-heat exchanger for ext. air conditioning) • Control of a frost protection pre-heater (frost protection heater prevents ice formation and replaces a ground to air heat exchanger in winter) • Constant flow control (permanent monitoring and balancing of the supply and extract air flows, fireplace compliant) • Control of a heating circuit (e.g. heating circuit pump or electric back-up duct heater up to 2.1 kW) – also with night economy • Several boost switches can be connected to the control panel • The MVHR unit can be operated by several programmers (e.g. one in the place of installation, another one in the living room). If a duct heater is used, the room temperature is recorded at the first control panel Option 2: Manual control • 7-leve fan speed control with OFF-function • Rapid ventilation possible • Possibility to connect additional, external boost switches • External OFF-contact • Clock timer for any day of the week (optional) • Fireplace compliant (optional – additional configuration software) • Balance adjustable between supply air and exhaust air fans • „supply air only“ or „exhaust air only“ (summer adjust.) • When fireplace compliant „exhaust air only“ locked • Filter monitor for change interval • Frost protection: a) Stepless reduction of supply air fan speed (not when fireplace compliant) when exhaust air temperature < 2°C b) Frost protection heater with independent control (optional) c) Ground heat exchanger (optional) Control units: Comfort control unit For automatic control Membrane keypad For manual control (LxBxT in mm: 158x125x32) Cable: IYSTY 2x2x0,6, max. 15 m, by customer (LxBxT in mm: 80x80x12) Cable: IYSTY 2x2x0,6, max. 15 m, by customer © Paul Wärmerückgewinnung GmbH • August-Horch-Straße 7 • 08141 Reinsdorf • Deutschland Tel: +49(0)375-303505-0 • Fax: +49(0)375-303505-55 • E-Mail: info@paul-lueftung.de • Internet: www.paul-lueftung.de