Download Operating Instructions Operating Instructions

Transcript
MVHR components:
Heat exchanger:
Fans:
Filters:
Central control unit:
(for option 1)
with defroster and
backup duct heater option
(for option 2)
Housing:
Duct connections:
Condensate drain:
Weight:
Electrical connection:
Protection class (acc. to EN 60335):
International protection (acc. to
DIN 40050):
Cable length:
Operation limit:
Mounting position:
Material: HX plastic
48 V DC (DC radial fan)
Filter class: G 4 (supply/extract air)
Option: pollen filter F 8 (supply air) – higher pressure loss
Lx Wx D (mm): 340x 300x 80
Lx Wx D (mm): 340x 300x 140
Lx Wx D (mm): 340x 300x 80
Galvanized steel plate, no thermal bridges, 40 mm heat insulation, sound-insulated
diameter 125 mm nipple measure
hose ¾“ (syphon – supplied by customer)
45 kg
230 V, 50 Hz, pre-wired
I
IP 41 (MVHR)
IP 20 (Control unit)
- mains cable: (by customer)
- between MVHR and central control unit: 3 m
- between central control unit and control panel: max. 15 m, (4-wire, screened control wire
IYSTY 2x2x0,6), supplied by customer
max. 40°C
horizontal, 2 % slope to condensate drain
Operating data:
Power input:
Volumetric flow rate:
Heat recovery rate:
Sound pressure level
Acc. to DIN EN ISO 3743-1:
max. 110 W
30 to 180 m³/h - 150 m³/h (at 100 Pa)
approx. 80 to 95 %
Fan stage / control
Step 1
Step 3
Step 5
Step 7
ca. 30%
ca. 50%
ca. 70%
ca.100%
3m distance
in free field
With installation in intermediate cover
Acc. to DIN 4109 Bbl. 1Tab. 26
23 dB(A)
27 dB(A)
32 dB(A)
33 dB(A)
< 20 dB(A)
Control:
Option 1: Automatic control
Standard functions
• 8 independent time programs can be defined and assigned to any
day of the week
• Manual adjustment of ventilation steps (off, minimum,normal,maximum)
• Control panel can be installed in any place in the house
• Ventilation steps programmable in 1% increments (30-100 % of maximum
fan power)
• Adjustable balance between supply and extract air fans
• Filter monitor for change interval
• Freeze protection for downstream hot water duct heater
• Manual stop in standby mode with limited power input below 2 W
Options (available at extra cost)
• Control of an electric valve (direct air intake or via ground heat exchanger)
or
a brine-defroster (brine/air-heat exchanger for ext. air conditioning)
• Control of a frost protection pre-heater (frost protection heater prevents ice
formation and replaces a ground to air heat exchanger in winter)
• Constant flow control (permanent monitoring and balancing of the supply
and extract air flows, fireplace compliant)
• Control of a heating circuit (e.g. heating circuit pump or electric back-up
duct heater up to 2.1 kW) – also with night economy
• Several boost switches can be connected to the control panel
• The MVHR unit can be operated by several programmers (e.g. one in the
place of installation, another one in the living room). If a duct heater is
used, the room temperature is recorded at the first control panel
Option 2: Manual control
• 7-leve fan speed control with OFF-function
• Rapid ventilation possible
• Possibility to connect additional, external boost
switches
• External OFF-contact
• Clock timer for any day of the week (optional)
• Fireplace compliant (optional – additional
configuration software)
• Balance adjustable between supply air and
exhaust air fans
• „supply air only“ or „exhaust air only“ (summer
adjust.)
• When fireplace compliant „exhaust air only“
locked
• Filter monitor for change interval
• Frost protection:
a) Stepless reduction of supply air fan speed
(not when fireplace compliant) when exhaust
air temperature < 2°C
b) Frost protection heater with independent
control (optional)
c) Ground heat exchanger (optional)
Control units:
Comfort control unit
For automatic control
Membrane keypad
For manual control
(LxBxT in mm: 158x125x32)
Cable: IYSTY 2x2x0,6,
max. 15 m, by customer
(LxBxT in mm:
80x80x12)
Cable: IYSTY 2x2x0,6,
max. 15 m, by customer
© Paul Wärmerückgewinnung GmbH • August-Horch-Straße 7 • 08141 Reinsdorf • Deutschland
Tel: +49(0)375-303505-0 • Fax: +49(0)375-303505-55 • E-Mail: info@paul-lueftung.de • Internet: www.paul-lueftung.de