Download FilterLab User's Guide
Transcript
M FilterLab® 2.0 User’s Guide Appendix D. FilterLab 2.0 Filter Response D.1 INTRODUCTION Bessel (low-pass) filters are mainly used for applications that need excellent step response. The emphasis is on phase and group delay; the frequency selectivity is poor compared to the other classical filter response functions (e.g., Butterworth). Some typical applications are: PWM communications channels, instrumentation and simple anti-aliasing filters for ADCs. Figure D-1 and Figure D-2 show the normalized frequency response. Increasing the filter order does not provide a significant improvement in the stop band rejection. Figure D-3 shows the normalized group delay, Figure D-4 shows the normalized step response. The step response overshoot is minimal. FilterLab 2.0 does not allow the user to select Bessel filters based on their frequency response. Use Figure D-3 and Figure D-4 to choose the order based on group delay and step response. Normalized Gain = G / HM (dB) 0.0 -0.5 n = 8 (top) through n = 1 (bottom) -1.0 -1.5 -2.0 -2.5 -3.0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Normalized Frequency = f / fP FIGURE D-1: 2003 Microchip Technology Inc. Normalized Bessel frequency response in the pass band. DS51419A-page 65