INTRODUCTION
Bessel (low-pass) filters are mainly used for applications that need excellent step
response. The emphasis is on phase and group delay; the frequency selectivity is poor
compared to the other classical filter response functions (e.g., Butterworth). Some
typical applications are: PWM communications channels, instrumentation and simple
anti-aliasing filters for ADCs.
Figure D-1 and Figure D-2 show the normalized frequency response. Increasing the
filter order does not provide a significant improvement in the stop band rejection.
Figure D-3 shows the normalized group delay, Figure D-4 shows the normalized step
response. The step response overshoot is minimal.
FilterLab 2.0 does not allow the user to select Bessel filters based on their frequency
response. Use Figure D-3 and Figure D-4 to choose the order based on group delay
and step response.
Normalized Gain
= G / HM (dB)
0.0
-0.5
n = 8 (top)
through
n = 1 (bottom)
-1.0
-1.5
-2.0
-2.5
-3.0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Normalized Frequency = f / fP
FIGURE D-1:
 2003 Microchip Technology Inc.
Normalized Bessel frequency response in the pass band.
DS51419A-page 65