Maintenance
6.3
Regular maintenance work
–
Check the oil filters and oil separators for leaks and tighten by hand,
if necessary.
–
Check oil level (procedure as described above).
Top up oil losses, if any.
Fig. 6.11: Drain off residual oil from compressed air/oil cooler
Flushing the oil circuit
Flushing the oil circuit with clean oil becomes necessary:
–
When the oil is excessively soiled.
–
Prior to changing the oil type.
Attention!
When flushing the oil circuit only use oil of the same brand you want to fill in
afterwards.
Page 62
–
Drain used oil completely (procedure as described above).
–
Leave used oil filters and separators inside the compressor.
–
Fill oil compressed air receiver with clean oil up to approx. one third of
the complete oil quantity.
–
Close oil filling socket.
–
Let compressor run for approx. 10 minutes.
–
Drain flushing oil and dispose of properly.
–
Change oil filter and oil separator cartridges (procedure as described
above).
–
Fill in new oil up to required oil level (procedure as described above).