Download DP User Manual
Transcript
To sort force curves by the result of the applied operation, the Filtering Series operation (Section 6.4.12) can be used. The selection of a threshold finally allows separating the curves into two folders, “filter-group-0” and “filter-group-1”. See Section 6.4.12 for more details. The behavior of the operations is exactly the same as for individual curves, as described in Section 6.4. It is recommended to test the operations on single curves first to become familiar with the operations. Once the parameters are adjusted for one curve they will automatically be used for the next curve, unless they are modified again. That means that all parameters can be adjusted for each curve separately if required. If parameters are left at the default values, for example using the full fit range for the Hertz fit, then the full range will be used for each curve even if the data have different lengths. As described in Section 6.4.15, series of force curve operations can be saved and loaded. The process files contain the order of operations as well as the parameters that have been adjusted to the processed curve. A sample curve can be loaded and the parameters optimized. The corresponding process file can then be used for automated and reproducible processing of a batch of curves. Right click in the force curve oscilloscope to Save or Load a Process. A file browser will open to save/load processes. The Open force curve button will open the actually displayed curve in a new window, where it can be processed like a single force file. This can be helpful, for instance, if one curve of a batch is selected to optimize the processing parameters. Batch processing is first used to scroll through all curves to find a sample curve, which is then opened separately to adjust all values for the corresponding processes. The process can be saved and finally applied to the whole batch of curves. On changing from one curve to the next, there are two different display options. If Autoscale XY is selected in the oscilloscope toolbar (highlighted with a red circle in the above screenshot), then the full data range will be shown for each curve. If it is not selected, then the same axis ranges are kept for each successive curve. Keep and apply to all will apply all operations with the same parameters to each curve successively through to the last force curve. This is equivalent to clicking Keep for each curve in turn without adjusting any parameters. Once curves have been processed or discarded, the button Undo will become active. This cancels the last Keep or Discard, going one place back up the list of force curves and removing the last set of parameter changes. DP Data Processing Software Version 4.2 73