Semiheated Building Checkbox
The checkbox should only be selected if all spaces are Semiheated and
the building has no cooling system.
Only the following building types and space categories can be specified
as ”Semiheated”
•
Whole Building types: Automotive Facility, Manufacturing
Facility, Parking Garage, Warehouse, and Workshop
•
Area Categories: Common Space Types: Active and Inactive
Storage, Hospital and Healthcare: Active Storage - Hospital,
Industrial and Auto Service: Automotive Facility Garage
Service/Repair, Detailed Manufacturing, Manufacturing Control
Room, Manufacturing Corridor/Transition, Manufacturing
Equipment Room, Manufacturing General - High Bay,
Manufacturing General - Low Bay, Library and Museum:
Museum Active and Inactive Storage, Warehouse and Parking:
Fine Material Storage, Medium/Bulky Material Storage, Parking
Garage - Attendant Only, Parking Garage - Pedestrian
No mechanical cooling can be specified when the building is designated
as ”Semiheated”.
The maximum allowable heating system capacity (listed on the
Envelope and Mechanical Compliance Certificates) is determined based
on the HDD65 of the location.
Mixed-Use Spaces
Spaces of mixed-use that have separate Semiheated spaces within the
building should be not be combined on one report. A separate data
file should be completed for each space.
Spaces of mixed use that include Residential and Non-Residential can
be combined on one report. The compliance calculations will be based
on the higher percentage of square footage of each space and/or the
stringency of the code between Residential and Non-Residential.
The following building types and space categories (when applicable for
the code selected) are defined as Residential (all other building types
and space categories that are not listed below are defined as NonResidential).