MP-01-inst-e 22-12-2010 14:58 Pagina 3 J, K, L, N, R, S, T thermocouple type input (opt.) Analogue inputs 7...8 7 8 7 8 7 8 9 10 A V B mA 7 9 10 A V B mA 8 9 10 P b com E P F - Respect the polarity shown; - To extend the connection, use always compensation cable of the correct type for the thermocouple used; - When present the shield must be connected to a proper earth (at only one end). Pt100, Pt1000 resistance thermometers (2, 3, 4 wires) input (opt.) Analogue inputs 7... 8 7 b com 8 7 8 7 8 9 10 A V B mA 7 8 9 10 P 9 A V b com A P E B mA F b com B 3 wires (PT100) b B 2 wires (PT1000) A TC 10 - The connection example refers only to input 7, for input 8 copy the same connection configuration; - When 3 wires system is used, always use cables of the same section (1mm2 min.)(max. resistance 20Ω/line); - When 2 wires system is used and the distance between the module and the sensor is 15 m, the use of a 1.5 mm2 section cable produces a 1°C (1.8°F) measure error. TC Line impedance: 150Ω max. Potentiometer input (opt.) V input (opt.) Analogue inputs 7... 8 0...10 V 7 7 8 7 8 9 10 A V B mA 7 8 9 10 P 9 10 A V b com E F b com V 8 8 7 8 9 10 E 7 8 9 10 A V B mA A V B mA 7 8 9 10 F 7 8 9 10 8 b com 9 A V B mA P b com P b com 9 A V P High level analogue inputs 7... 8 -20... 20/0... 20/4... 20 mA 7 7 P R 7 8 10 7 B mA P High level analogue inputs 7... 8 -10... +10V/0...10 V Analogue inputs 7... 8 8 7 High level inputs (opt.) 10 E B mA F b com 8 7 8 7 8 9 10 A V B mA 7 8 9 10 P b com 9 10 A V P E B mA F b com R R = 100Ω... 10kΩ max. V V V 4...20 mA 4...20 mA Digital Inputs 1...8 Type II (EN61131-2) - Respect the polarity; - When present the shield must be connected to a proper earth (at only one end). Contact input 1 2 Source (PNP) device PNP device A NO contact 1 1 2 1 2 A 2 B B 9 10 9 10 Additional terminal block Additional terminal block +24Vdc +24Vdc Connect to +24Vdc Connect to +24Vdc Analogue outputs 1...4 (opt.) - The user can choose the number of analogue output installed in the central unit (0, 2 or 4 outputs); - Respect the polarity. Analogue load 1 2 3 4 11 12 13 14 11 12 13 14 + + + - - Digital Output 1...8 (PNP) Source Type - 1 E 1 1 Load Respect the polarity shown F - 24 Vdc, 0.5A digital outputs - Respect the polarity - When present the shield must be connected to a proper earth (at only one end). Source (PNP) device + 11 12 13 14 - - Respect the polarity. - When present the shield must be connected to a proper earth (at only one end); - If the input device needs to be powered by the module, verify that the current consumption does not exceed the power supply limits. Load 9 9 ... POWER ... 10 11 ... 10 11 ... ... 10 11 ... ... A B 0V Additional D terminal block