Download Installation Manual

Transcript
MP-01-inst-e
22-12-2010
14:58
Pagina 3
J, K, L, N, R, S, T thermocouple type input (opt.)
Analogue inputs 7...8
7
8
7
8
7
8 9 10
A
V
B
mA
7
9
10
A
V
B
mA
8 9 10
P
b
com
E
P
F
- Respect the polarity shown;
- To extend the connection, use always
compensation cable of the correct type
for the thermocouple used;
- When present the shield must be connected to a proper earth (at only one
end).
Pt100, Pt1000 resistance thermometers (2, 3, 4 wires) input (opt.)
Analogue inputs 7... 8
7
b
com
8
7
8
7
8 9 10
A
V
B
mA
7
8 9 10
P
9
A
V
b
com
A
P
E
B
mA
F
b
com
B 3 wires
(PT100)
b
B 2 wires
(PT1000)
A
TC
10
- The connection example refers only to
input 7, for input 8 copy the same connection configuration;
- When 3 wires system is used, always use
cables of the same section (1mm2
min.)(max. resistance 20Ω/line);
- When 2 wires system is used and the distance between the module and the sensor
is 15 m, the use of a 1.5 mm2 section
cable produces a 1°C (1.8°F) measure
error.
TC
Line impedance: 150Ω max.
Potentiometer input (opt.)
V input (opt.)
Analogue inputs 7... 8
0...10 V
7
7
8
7
8 9 10
A
V
B
mA
7
8 9 10
P
9
10
A
V
b
com
E
F
b
com
V
8
8
7
8 9 10
E
7
8 9 10
A
V
B
mA
A
V
B
mA
7
8 9 10
F
7
8 9 10
8
b
com
9
A
V
B
mA
P
b
com
P
b
com
9
A
V
P
High level analogue inputs 7... 8
-20... 20/0... 20/4... 20 mA
7
7
P
R
7
8
10
7
B
mA
P
High level analogue inputs 7... 8
-10... +10V/0...10 V
Analogue inputs 7... 8
8
7
High level inputs (opt.)
10
E
B
mA
F
b
com
8
7
8
7
8 9 10
A
V
B
mA
7
8 9 10
P
b
com
9
10
A
V
P
E
B
mA
F
b
com
R
R = 100Ω... 10kΩ max.
V
V
V
4...20 mA
4...20 mA
Digital Inputs 1...8 Type II (EN61131-2)
- Respect the polarity;
- When present the shield must be connected to a proper earth (at only one end).
Contact input
1
2
Source (PNP) device
PNP
device
A
NO
contact
1
1
2
1
2
A
2
B
B
9 10
9 10
Additional
terminal block
Additional
terminal block
+24Vdc
+24Vdc
Connect
to +24Vdc
Connect
to +24Vdc
Analogue outputs 1...4 (opt.)
- The user can choose the number of
analogue output installed in the central
unit (0, 2 or 4 outputs);
- Respect the polarity.
Analogue load
1
2 3 4
11
12
13 14
11 12 13 14
+
+
+
-
-
Digital Output 1...8 (PNP) Source Type
-
1
E
1
1
Load
Respect the polarity
shown
F
- 24 Vdc, 0.5A digital outputs
- Respect the polarity
- When present the shield must be connected
to a proper earth (at only one end).
Source (PNP) device
+
11 12 13 14
-
- Respect the polarity.
- When present the shield must be connected to a proper earth (at only one end);
- If the input device needs to be powered by
the module, verify that the current
consumption does not exceed the power
supply limits.
Load
9
9
... POWER
... 10 11
... 10 11
...
... 10 11
...
...
A
B
0V
Additional
D terminal
block